Article Abstract

Introduction: Increased accuracy when using fiducial markers for prostate localisation is well documented. This project aimed to establish the improvement in accuracy when using gold markers for daily prostate localisation, to assess patient satisfaction and morbidity from the transrectal implantation of gold seed markers and establish staff attitudes towards the newly introduced processes.

Methods: Twenty patients with prostate cancer had three gold seeds implanted into the base, apex and central zone of the prostate transrectally using ultrasound guidance. Surveys were conducted to assess staff and patient satisfaction with the process of gold seed localisation. The gold markers were used to localise the prostate on a daily basis using megavoltage electronic portal imaging. Measurements were taken to establish the increase in accuracy when using gold fiducial markers compared with using the surrounding bony anatomy.

Results: Inter-fraction motion (1 standard deviation (SD)) of the fiducial markers was 2.20, 4.28 and 4.27 mm in the LR, SI and AP directions, respectively. Intra-fraction prostate motion (1 SD) was measured as 0.8 mm LR, 1.1 mm SI and 2.0 mm AP. The patient survey showed that the insertion and associated side effects were acceptable, with 5% of patients stating that the seed insertion was worse than the prostate biopsy, and 23.1% of patients experienced short duration (1-2 days) haematuria. The staff survey showed that daily online image guidance was achievable without affecting patient throughput. Thirty percent of treatment staff believed that performing online daily localisation did not add any extra time to a standard treatment, and the remaining 70% thought that the added time was minimal (2-4 min).

Conclusions: Gold fiducial markers are an accurate, reliable and tolerable method of daily prostate localisation.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1754-9485.2011.02278.xDOI Listing

Publication Analysis

Top Keywords

fiducial markers
16
prostate localisation
12
prostate
8
accuracy gold
8
gold markers
8
daily prostate
8
patient satisfaction
8
gold seed
8
gold fiducial
8
markers
7

Similar Publications

: The aim of this study was to compare the outcomes of stiff wire-based 2D3D, 3D3D image fusion (IF), and non-image fusion techniques for simple zone 2 and zone 3 TEVAR cases in terms of radiation exposure, contrast dose, and fusion and projection accuracy. : A single-center retrospective observational study was conducted based on data gathered from patients who underwent TEVAR between 2016 and 2023 at our tertiary aortic referral center. Those who underwent Z2 and Z3 TEVAR during the indicated period were included.

View Article and Find Full Text PDF

: Accurate target definition, treatment planning and delivery increases local tumor control for radiotherapy by minimizing collateral damage. To achieve this goal for uveal melanoma (UM), tantalum fiducial markers (TFMs) were previously introduced in proton and photon beam radiotherapy. However, TFMs cause pronounced scattering effects in imaging that make the delineation of small tumors difficult.

View Article and Find Full Text PDF

Purpose: To investigate the feasibility and accuracy (trueness and precision) of facial scanning and virtual patient representation (VPR).

Materials And Methods: One participant was recruited and informed consent was obtained. VPR was performed 30 times with a custom fabricated intraoral scan body (ISB).

View Article and Find Full Text PDF

Background: Various methods exist to correct for intrafraction motion (IFM) of the prostate during radiotherapy. We sought to characterize setup corrections in our practice informed by the TrueBeam Advanced imaging package, and analyze factors associated with IFM.

Methods: 132 men received radiation therapy for prostate cancer with a volumetric modulated arc therapy technique.

View Article and Find Full Text PDF

A co-registration method to validate optical coherence tomography in the breast surgical cavity.

Heliyon

January 2025

BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Australia.

Breast-conserving surgery accompanied by adjuvant radiotherapy is the standard of care for patients with early-stage breast cancer. However, re-excision is reported in 20-30 % of cases, largely because of close or involved tumor margins in the specimen. Several intraoperative tumor margin assessment techniques have been proposed to overcome this issue, however, none have been widely adopted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!