A radiographic analysis of implant component misfit.

Int J Oral Maxillofac Implants

Division of Restorative Dentistry and Periodontology, Dublin Dental School and Hospital, Trinity College, Dublin, Ireland.

Published: December 2011

Purpose: Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

Materials And Methods: Twelve internal-connection and 12 external-connection implant analogs with impression copings were assembled, with radiolucent washers interposed, to produce vertical misfits of 0, 12.7, 25, 38, 51, 63, 76, 88, 102, 114, 127, and 190 μm. A custom-made positioning apparatus was used to obtain radiographs of the components at angulations between 0 and 35 degrees. The images were randomized, and three experienced examiners assessed whether a gap was visible at the interface. Their responses were compared to the actual status of the samples, and a probability model was constructed to predict the likelihood of a correct answer at any combination of gap and angle.

Results: The relative angulation of the radiograph and the dimension of the gap were the most significant factors affecting an examiner's diagnostic ability. A 0-μm gap viewed at 0 degrees was the combination most accurately diagnosed. Implant component misfits as small as 12.7 μm were reliably detected with radiographs up to 5 degrees from the orthogonal projection; this was similar with configurations of 25 to 38 μm/10 degrees and 51 μm/15 degrees. There was good (inter-)examiner reliability. Neither the type of component used nor the radiographic media used influenced diagnostic ability.

Conclusion: The angulation of the x-ray beam relative to implant components needs to be controlled when using radiographs to detect component misfit.

Download full-text PDF

Source

Publication Analysis

Top Keywords

component misfit
12
implant component
8
implant components
8
implant
6
component
5
gap
5
degrees
5
radiographic analysis
4
analysis implant
4
misfit
4

Similar Publications

Anisotropically Epitaxial P-N Heterostructures Actuating Efficient Z-Scheme Photocatalytic Water Splitting.

Small

January 2025

Key Laboratory of Eco-chemical Engineering, International S&T Cooperation Foundation of Eco-chemical Engineering and Green Manufacture, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, P. R. China.

Crafting anisotropically epitaxial p-n heterostructures with Z-scheme charge transmission is a promising avenue toward excellent photocatalytic efficiency, yet the large lattice mismatch and diverse crystal growth habits between components have often arisen as a big challenge to this goal. Here, anisotropically epitaxial p-n heterostructures with 19.8% lattice mismatch are obtained via a dynamics-mediated seeded growth tactic under reaction temperature as low as 60 °C.

View Article and Find Full Text PDF

Accurate characterisation of seismic source mechanisms in mining environments is crucial for effective hazard mitigation, but it is complicated by the presence of anisotropic geological conditions. Neglecting anisotropic effects during moment tensor (MT) inversion introduces significant distortions in the retrieved source characteristics. In this study, we investigated the impact of ignoring anisotropy during MT inversion on the reliability of hazard assessment.

View Article and Find Full Text PDF

Coastal populations are susceptible to relative sea-level (RSL) rise and accurate local projections are necessary for coastal adaptation. Local RSL rise may deviate from global mean sea-level rise because of processes such as geoid change, glacial isostatic adjustment (GIA), and vertical land motion (VLM). Amongst all factors, the VLM is often inadequately estimated.

View Article and Find Full Text PDF

Full-arch zirconia restorations on implants have gained popularity due to zirconia's strength and aesthetics, yet they are still associated with challenges like structural fractures, peri-implant complications, and design misfits. Advances in CAD/CAM and digital workflows offer potential improvements, but a technique that consistently addresses these issues in fixed, full-arch, implant-supported prostheses is needed. This novel technique integrates a facially and prosthetically driven treatment approach, which is divided into three phases: data acquisition, restoration design, and manufacturing/delivery.

View Article and Find Full Text PDF

A one-step fabrication of soft-magnetic high entropy alloy fiber with excellent strength and flexibility.

Nat Commun

December 2024

CAS Key Laboratory of Magnetic Materials and Devices, Zhejiang Province Key Laboratory of Magnetic Materials and Application Technology, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang, China.

Soft-magnetic fibers (SMFs) play a crucial role in energy conversion, transmission, and storage within electronic devices. However, conventional SMFs have poor plasticity and are therefore difficult to withstand long-term tensile, torsional, and shear deformation. A high fraction of grain boundaries could improve plastic deformability of conventional SMFs, but deteriorates the coercivity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!