A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Resonance frequency analysis as a reliable criterion for early loading of sandblasted/acid-etched active surface implants placed by the osteotome sinus floor elevation technique. | LitMetric

Purpose: This study was intended to investigate, through resonance frequency analysis (RFA), the stability of implants placed in an early loading protocol via the osteotome sinus floor elevation technique in the posterior maxilla. All implants featured a sandblasted/acid-etched active surface.

Materials And Methods: An early loading protocol was considered for patients in whom implants with a sandblasted, large-grit/acid-etched active surface (SLActive) were placed in the posterior maxilla by the osteotome sinus floor elevation technique. Implant stability, which was measured by RFA at surgery and at weekly intervals for the following 6 weeks, was used as the most significant inclusion criterion. At the end of the stability observation period, only implants with a stability quotient of 65 or higher were loaded. Implants were followed for 2 years.

Results: Twenty-seven patients received 42 implants, 40 of which were subjected to an early loading protocol 6 weeks after placement. Two years after loading, all 40 implants were surviving, without clinically or radiographically detectible complications.

Conclusion: An early loading protocol can be used for SLActive implants placed in the posterior maxilla via the osteotome sinus floor elevation technique if their stability is confirmed by RFA.

Download full-text PDF

Source

Publication Analysis

Top Keywords

early loading
20
osteotome sinus
16
sinus floor
16
floor elevation
16
elevation technique
16
loading protocol
16
posterior maxilla
12
implants
9
resonance frequency
8
frequency analysis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!