Background: Arthroscopic procedures for reconstruction of acromioclavicular (AC) joint separations are increasingly used in clinical practice. Multiple surgical techniques exist, but there are still few data on biomechanical performances of commonly used arthroscopic techniques and fixation methods.
Hypothesis: Single and double clavicular tunnel reconstructions show comparable primary stability with a modified Weaver-Dunn procedure, and double tunnel constructs show superior horizontal stability.
Study Design: Controlled laboratory study.
Methods: The AC joints of 40 cadaveric shoulders were tested for anterior, posterior, and superior translation (70-N load) and maximal load to failure (superior) with the MTS 858 Bionix II Servohydraulic testing system. Shoulders were assigned to 4 groups: (1) native (n = 18), (2) coracoclavicular (CC) reconstruction with 1 clavicular and 1 coracoid tunnel (SCT) fixed with a suture pulley and 2 buttons (n = 8), (3) CC reconstruction with 2 clavicular and 1 coracoid tunnel (DCT) fixed with a suture pulley and 3 buttons (n = 8), and (4) modified Weaver-Dunn reconstruction (n = 6).
Results: Native specimens showed a mean anterior translation of 7.92 mm (±1.69 mm), a mean posterior translation of 7.84 mm (±2.09 mm), and a superior translation of 4.28 mm (±1.81 mm). Maximal load to failure was 579.44 N (±148.01 N). The SCT technique showed a mean anterior translation of 5.81 mm (±1.16 mm), posterior translation of 8.30 mm (±1.94 mm), and a superior translation of 2.28 mm (±0.52 mm). The maximal load to failure was 591.35 N (±231.17 N). Anterior and superior translations were significantly less compared with the native specimen (P = .005 and P = .003). The DCT technique had an anterior translation of 4.68 mm (±0.6 mm), posterior translation of 6.85 mm (±0.83 mm), and superior translation of 2.09 mm (±0.86 mm). The mean maximal load to failure was 651.16 N (±226.93 N). Anterior and superior translations were significantly less compared with the native specimens (P = .000 and P = .001). No statistically significant differences were shown between SCT and DCT reconstruction for all measurements (P > .05). One reconstruction of the modified Weaver-Dunn procedure failed directly after mounting it into the testing device. The remaining 5 showed a mean anterior translation of 11.36 mm (±3.17 mm), a mean posterior translation of 13.51 mm (±2.21 mm), and a mean superior translation of 3.31 mm (±0.47 mm). Anterior and posterior translations were significantly increased compared with the native specimen (P = .019 and P = .000). The mean maximal load to failure measured 311.13 N (±52.2 N) and was significantly less compared with the native specimen (P = .000). The Weaver-Dunn technique showed significantly less maximal load to failure and more anterior and posterior translation compared with SCT and DCT (P ≤ .05).
Conclusion: Isolated reconstruction of the CC ligaments using single and double clavicular tunnel techniques results in a high load to failure for superior translation, which is equal to the native stability, and less translation in all 3 directions as well as higher superior stability when compared with the modified Weaver-Dunn procedure. A potential drawback is the risk of coracoid fracture, as the high load to failure of the device may exceed load to failure of cortical bone prior to device breakage.
Clinical Relevance: Single clavicular tunnel arthroscopic reconstructions of the coracoacromial ligaments show good biomechanical results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0363546511416784 | DOI Listing |
Background: Acne is an inflammatory skin disease afflicting the majority of the world's population at some point in their lifetime, and is seen to be chronic in about 50% of cases. Acne leads to significant social withdrawal, depression, and disfiguring scars in many cases. Available treatments are characterized by high rates of relapse, dangerous side effects, and social stigma, which often leads to poor patient compliance and treatment failure.
View Article and Find Full Text PDFJ Mater Sci Mater Med
January 2025
Clinic of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.
Although implants have undergone a remarkable development over the past decades, modern implants still show complications that make the improvement of materials necessary. The presented study investigates the load-bearing capacity of an experimental dental implant made of a niobium alloy (Nb1Zr) compared to identical implants made of Ti6Al4V using chewing simulation for artificial aging. Eight implants each with an experimental design were manufactured from Nb1Zr and Ti6Al4V.
View Article and Find Full Text PDFData Brief
February 2025
Department of Mechanical Engineering, Brawijaya University, Indonesia.
Crash box development is carried out continuously to obtain a lightweight design and high energy absorption. This dataset presents the results of a crash box experiments. Quasi-static testing of aluminum, honeycomb, and hybrid tube specimens was carried out using a universal testing machine.
View Article and Find Full Text PDFBrain Spine
December 2024
Orthopedic Surgery Department, Unidade Local de Saúde de Braga, Portugal - Sete Fontes, São Victor, 4710-243, Braga, Portugal.
Introduction: Thoracolumbar (TL) transition trauma is frequent and challenging. Although short- (SSPF) and long-segment posterior fixation (LSPF) are its mainstay treatment, little is known about their failure rates and reasons behind it.
Research Question: understand why TL instrumentations fail and what factors influence it.
J Strength Cond Res
December 2024
School of Kinesiology, University of Michigan, Ann Arbor, Michigan.
Motlagh, JG and Lipps, DB. The contribution of muscular fatigue and shoulder biomechanics to shoulder injury incidence during the bench press exercise: A narrative review. J Strength Cond Res 38(12): 2147-2163, 2024-Participation in competitive powerlifting has rapidly grown over the past two decades.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!