This study tested the hypothesis that the compliance (C) and viscoelasticity (K) of the forearm vascular bed are controlled by myogenic and/or α-adrenergic receptor (αAR) activation. Heart rate (HR) and waveforms of brachial artery blood pressure (Finometer) and forearm blood flow (Doppler ultrasound) were measured in baseline conditions and during infusion of noradrenaline (NA; αAR agonist), with and without phentolamine (αAR antagonist; n = 10; 6 men and 4 women). These baseline and αAR-agonist-based measures were repeated when the arm was positioned above or below the heart to modify the myogenic stimulus. A lumped Windkessel model was used to quantify the values of forearm C and K in each set of conditions. Baseline forearm C was inversely, and K directly, related to the myogenic load (P < 0.001). Compared with saline infusion, C was increased, but K was unaffected, with phentolanine, but only in the 'above' position. Compliance was reduced (P < 0.001) and K increased (P = 0.06) with NA infusion (main effects of NA) across arm positions; phentolamine minimized these NA-induced changes in C and K for both arm positions. Examination of conditions with and without NA infusion at similar forearm intravascular pressures indicated that the NA-induced changes in C and K were due largely to the concurrent changes in blood pressure. Therefore, within the range of arm positions used, it was concluded that vascular stiffness and vessel wall viscoelastic properties are acutely affected by myogenic stimuli. Additionally, forearm vascular compliance is sensitive to baseline levels of αAR activation when transmural pressure is low.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1113/expphysiol.2011.059188 | DOI Listing |
Interv Pain Med
March 2025
Department of Anesthesiology, Perioperative, and Pain Medicine, Weill Cornell Medicine, New York, NY, USA.
•: The AI-assisted VR module enables learners to engage in a 360-degree immersive environment, manipulating holographic anatomy models and simulating fluoroscopic guidance to perform the Gasserian ganglion block.•: Key anatomical landmarks, like the foramen ovale, are highlighted, and proper C-arm positioning is demonstrated, helping practitioners localize the target area for needle advancement.•: The module includes AI-driven multi-language options and AI-generated multiple-choice questions to enhance learning and retention.
View Article and Find Full Text PDFJ Neuroeng Rehabil
January 2025
Department of BioMechanical Engineering, Delft University of Technology, Mekelweg 2, Delft, 2628 CD, South-Holland, The Netherlands.
Duchenne Muscular Dystrophy (DMD) progressively leads to loss of limb function due to muscle weakness. The incurable nature of the disease shifts the focus to improving quality of life, including assistive supports to improve arm function. Over time, the passive joint impedance (Jimp) of people with DMD increases.
View Article and Find Full Text PDFSci Rep
January 2025
Zhongyuan University of Technology, Zhengzhou, 450007, China.
This paper studies the practical prescribed-time control problem for dual-arm robots handling an object with output constraints. Firstly, by utilizing the property that the sum of internal forces in the grasping space is zero, the system model is obtained and decomposed into the contact force model and free motion model, which are orthogonal to each other. Furthermore, by combining the performance function and constraint function, the original system tracking error is transformed to a new one, whose boundedness can ensure that the original system variable converges to the predetermined range within the specified time.
View Article and Find Full Text PDFChin J Traumatol
January 2025
Department of Emergency Surgery and Orthopaedic Surgery, Qilu Hospital of Shandong University, Jinan, 250012, China. Electronic address:
Purpose: The fixation method commonly employed worldwide for treating unstable fractures of the posterior pelvic ring is the percutaneous iliosacral screw technique. However, prolonged operation time and frequent fluoroscopies result in surgical risks. This study aimed to investigate whether a new triangulation method could reduce operative and fluoroscopy times and increase the accuracy of screw placement.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
January 2025
Roth | McFarlane Hand & Upper Limb Center, St Joseph's Health Care London, London, ON, Canada.
Background: Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!