A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The new advanced membrane gas exchanger. | LitMetric

Current membrane oxygenators are constructed for patients with a body surface under 2.2 m(2). If the body surface exceeds 2.5 m(2), commercially available devices may not allow adequate oxygenation during cardiopulmonary bypass. To address this, a hollow-fiber oxygenator with an enlarged contact surface of 1.81 m(2) was tested. In an experimental set-up, six calves of mean weight 85.4 ± 3 kg were connected to cardiopulmonary bypass. They were randomly assigned to a standard oxygenator (n = 3; ADMIRAL, Euroset, Medola, Italy) with a surface of 1.35 m(2) or to an enlarged surface oxygenator (n = 3; AMG, Euroset). Blood samples were taken before bypass, after 10 min on bypass, and after 1, 2, 5 and 6 h of perfusion. Analysis of variance was used for repeated measurements. The mean flow rate was 6.5 l/min for 6 h. The total oxygen transfer at 6 h was significantly higher in the high-surface group (P < 0.05). Blood trauma, evaluated by plasma hemoglobin and lactate dehydrogenase levels, did not detect any significant hemolysis. Thrombocytes and white blood cell count profiles showed no significant differences between the two groups at 6 h of perfusion (P = 0.06 and 0.80, respectively). At the end of testing, no clot deposition was found in the oxygenator, and there was no evidence of peripheral emboli. The results suggest that the new oxygenator allows very good gas transfer and may be used for patients with a large body surface area.

Download full-text PDF

Source
http://dx.doi.org/10.1510/icvts.2011.276873DOI Listing

Publication Analysis

Top Keywords

body surface
12
cardiopulmonary bypass
8
surface
6
oxygenator
5
advanced membrane
4
membrane gas
4
gas exchanger
4
exchanger current
4
current membrane
4
membrane oxygenators
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!