A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Estimation of capsaicin through scanning densitometry and evaluation of different varieties of capsicum in India. | LitMetric

Capsicum annuum L. (family: Solanaceae) possesses therapeutic benefits for the treatment of rheumatism, neuropathy, psoriasis, flatulence and so on. In this study fruits of four different varieties of C. annuum from four different geographical regions in India were evaluated based on their total content of capsaicin. Ethanol extracts of the fruits were used. HPTLC plates were developed in a mobile phase containing benzene, ethyl acetate and methanol (75:20:5). Densitometric scanning was performed at a wavelength of 283 nm in the absorbance mode. The calibration curve was described by the equation Y=393.587+3.836*X with a correlation coefficient (r) of 0.99890. The content of capsaicin in Nagaland, Manipur, West Bengal and Shimla varieties was found to be 3.71%, 1.78%, 0.54% and 0.06%, respectively. The developed densitometric method was found to be specific, accurate and precise. A recovery study and precision showed low levels of %RSD values. The linearity range of the curve for capsaicin was found to be 300-900 ng per spot. The limit of detection and the limit of quantification values were determined to be 31 and 94 ng, respectively, proving the sensitivity of the method. Thus the method can be used to control the total content of capsaicin on an industrial scale.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14786419.2010.535169DOI Listing

Publication Analysis

Top Keywords

content capsaicin
12
total content
8
estimation capsaicin
4
capsaicin scanning
4
scanning densitometry
4
densitometry evaluation
4
evaluation varieties
4
varieties capsicum
4
capsicum india
4
india capsicum
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!