The purpose of this study was to evaluate the safety and efficacy of transcatheter atrial septal defect (ASD) closure guided by transthoracic echocardiography (TTE). Since 2004, ASD closure was performed successfully in total 337 patients. Transthoracic echocardiography guidance was used in 206 patients (61.1%) (group 1). Closure was guided by transesophageal echocardiography under general anesthesia in patients with poor transthoracic acoustic windows, defects with aneurysmatic septum and/or multiple defects in 131 patients (38.9%) (group 2). The median age (9 vs. 16 years, P < 0.001), mean defect diameter (14.9 ± 4 vs. 17.2 ± 5 mm, P < 0.001), ratio of complex atrial septal defect (14 vs. 34%, P = 0.01), the median balloon stretch dimensions (21 vs. 18.7 mm, P = 0.003) and the median device diameters (22 vs. 19 mm, P < 0.001) were significantly greater in group 2 compared to group 1. Both the median procedure time and the median fluoroscopy time was significantly shorter in group 1 (60 vs. 75; and 13 vs. 16.5 min; P < 0.0001 and P < 0.0001, respectively). The incidence of residual shunt did not differ significantly in two groups during follow up. Transthoracic echocardiography guidance during transcatheter ASD closure is safe and effective in children and in many adults. Even complex ASDs could be closed with TTE in patients with good acoustic windows. Performing the procedure under TTE guidance significantly reduces procedure time and also provides increased patient's comfort.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10554-011-9933-zDOI Listing

Publication Analysis

Top Keywords

atrial septal
12
asd closure
12
transthoracic echocardiography
12
guidance transcatheter
8
children adults
8
septal defect
8
closure guided
8
echocardiography guidance
8
acoustic windows
8
group median
8

Similar Publications

A 21-year-old man, known case of the repaired congenital heart disease, developed complete atrioventricular block (AVB) one week after simultaneous bioprosthetic pulmonary and tricuspid valve replacement and atrial septal defect repair. Considering the persistence of the AVB, it was decided to implant a permanent pacemaker. After considering all available options and the issues related to the patient, it was decided to implant a leadless pacemaker (LLP).

View Article and Find Full Text PDF

Background: Electrocardiograms (EKGs) are routinely performed in pregnant patients with pre-existing cardiovascular disease. However, in pregnant patients with congenital heart disease (CHD), EKG changes during gestation have not been explored.

Methods: We performed a retrospective study of pregnant patients with CHD enrolled in the STORCC initiative.

View Article and Find Full Text PDF

Aims: Atrial septal defect (ASD) and partial abnormal pulmonary venous connection (PAPVC) are noncyanotic congenital heart defects (CHD) that produce a left-to-right shunt. This single-center retrospective study aimed to assess the hemodynamic impact of isolated ASD, isolated PAPVC, and ASD-associated PAPVC using cardiovascular magnetic resonance (CMR).

Methods And Results: From our CMR registry (2002-2024), 110 patients were included: isolated ASD (n=64), isolated PAPVC (n=18), ASD-associated PAPVC (n=28, mostly sinus venosus septal defects).

View Article and Find Full Text PDF

Background: To investigate the optimization of leadless pacemaker placement and to assess its impact on heart synchronization and tricuspid regurgitation.

Results: A clinical trial was conducted involving 53 patients who underwent leadless pacemaker implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine and Hangzhou First People's Hospital between March 2022 and February 2023. Implantation site localization was determined using the 18-segment method under RAO 30° imaging.

View Article and Find Full Text PDF

This case report presents a 37-year-old male with a complex medical history, including HIV, chronic methamphetamine and cocaine use, and an atrial septal defect, who developed severe pulmonary arterial hypertension (PAH), biventricular failure, and recurrent stroke. The patient was admitted with acute neurological deficits and respiratory failure, which rapidly progressed despite intensive management. Laboratory and imaging studies revealed severe cardiac dysfunction and elevated pulmonary vascular resistance.

View Article and Find Full Text PDF