Compactness of lateral shearing interferometers.

Appl Opt

Office National d'Etudes et de Recherches Aérospatiales, Palaiseau, France.

Published: August 2011

Imaging lateral shearing interferometers are good candidates for airborne or spaceborne Fourier-transform spectral imaging. For such applications, compactness is one key parameter. In this article, we compare the size of four mirror-based interferometers, the Michelson interferometer with roof-top (or corner-cube) mirrors, and the cyclic interferometers with two, three, and four mirrors, focusing more particularly on the last two designs. We give the expression of the translation they induce between the two exiting rays. We then show that the cyclic interferometer with three mirrors can be made quite compact. Nevertheless, the Michelson interferometer is the most compact solution, especially for highly diverging beams.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.50.004656DOI Listing

Publication Analysis

Top Keywords

lateral shearing
8
shearing interferometers
8
michelson interferometer
8
three mirrors
8
compactness lateral
4
interferometers
4
interferometers imaging
4
imaging lateral
4
interferometers good
4
good candidates
4

Similar Publications

Objective: The complex mix of factors, including hemodynamic forces and wall remodeling mechanisms, that drive intracranial aneurysm growth is unclear. This study focuses on the specific regions within aneurysm walls where growth occurs and their relationship to the prevalent hemodynamic conditions to reveal critical mechanisms leading to enlargement.

Methods: The authors examined hemodynamic models of 67 longitudinally followed aneurysms, identifying 88 growth regions.

View Article and Find Full Text PDF

Instability remains one of the most common indications for revision after total knee arthroplasty. To gain a better understanding of how an implant will perform in vivo and support surgeons in selecting the most appropriate implant design for an individual patient, it is crucial to evaluate the implant constraint within clinically relevant ligament and boundary conditions. Therefore, this study investigated the constraint of three different implant designs (symmetrical implants with and without a post-cam mechanism and an asymmetrical medial-stabilized implant) under anterior-posterior shear forces and internal-external rotation moments at different flexion angles in human cadaveric knees using a six-degrees-of-freedom joint motion simulator.

View Article and Find Full Text PDF

Lateralisation in reverse shoulder arthroplasty - A narrative review.

J Clin Orthop Trauma

March 2025

Department of Orthopaedics, Woodend Hospital, Aberdeen, AB15 6XS, UK.

Reverse shoulder arthroplasty (RSA) has witnessed a significant advancement with the introduction of lateralisation techniques, aiming to enhance shoulder function and implant durability. Traditional medialised designs, following Grammont's principles, have encountered challenges such as scapular notching, reduced rotational strength, and instability. In contrast, lateralisation methods, which reposition the joint center of rotation laterally on the glenoid, humerus, or both, seek to improve deltoid leverage, optimize the rotator cuff muscles' length-tension relationship, and enhance joint stability.

View Article and Find Full Text PDF

This paper explores a multi-directional (multiple directional) shearing synchronous polarization phase-shifting interferometer that utilizes a birefringent crystal displacer. This design effectively mitigates nonlinear issues and environmental influences commonly encountered in synchronous phase-shifting interferometry. Additionally, it enables the acquisition of shear wavefront information from multiple directions.

View Article and Find Full Text PDF

With the advancement of ecological and environmental protection construction, the research on the modification of expansive soil using environmentally friendly polymers can make up for the harm to the ecological environment caused by traditional modification. Mechanical and microscopic properties of modified expansive soils were analyzed through indoor tests. The results showed that the liquid limit and plasticity index decreased by 52.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!