A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy assessment of the axial images obtained from cone beam computed tomography. | LitMetric

Objective: The aim of this study was to evaluate accuracy of linear measurements assessed from axial tomograms and the influence of the use of different protocols in two cone beam CT (CBCT) units.

Methods: A cylinder object consisting of Nylon® (Day Brazil, Sao Paulo, Brazil) with radiopaque markers was radiographically examined applying different protocols from NewTom 3G(TM) (Quantitative Radiology s.r.l, Verona, Veneto, Italy) and i-CAT(TM) (Imaging Sciences International, Hatfield, PA) units. Horizontal (A-B) and vertical (C-D) distances were assessed from axial tomograms and measured using a digital calliper that provided the gold standard for actual values.

Results: There were differences when considering acquisition protocols to each CBCT unit. Concerning all analysed protocols from i-CAT(TM) and Newtom 3G(TM), both A-B and C-D distances presented underestimated values. Measurements of the axial images obtained from NewTom 3G(TM) (6 inch 0.16 mm and 9 inch 0.25 mm) were similar to the ones obtained from i-CAT(TM) (13 cm 20 s 0.3 mm, 13 cm 20 s 0.4 mm and 13 cm 40 s 0.25 mm).

Conclusion: The use of different protocols from CBCT machines influences linear measurements assessed from axial images. Linear distances were underestimated in both equipments. Our findings suggest that the best protocol for the i-CAT(TM) is 13 cm 20 s 0.3 mm and for the NewTom 3G(TM), the use of 6 inch or 9 inch is recommended.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3520333PMC
http://dx.doi.org/10.1259/dmfr/88722046DOI Listing

Publication Analysis

Top Keywords

newtom 3gtm
16
axial images
12
assessed axial
12
cone beam
8
linear measurements
8
measurements assessed
8
axial tomograms
8
c-d distances
8
protocols cbct
8
i-cattm newtom
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!