Background: The main Ebstein anomaly (EA) repairs are based on the monocusp reconstruction of the tricuspid valve and are limited by the frequent need for replacement or the high recurrence of valve regurgitation.
Objective: To evaluate the feasibility and effects of anatomical repair of Ebstein's anomaly using the cone reconstruction technique on patients' clinical evaluation, tricuspid valve function and right ventricular morphology.
Methods: We compared the clinical, echocardiographic and radiological data of 52 consecutive patients, with a mean age of 18.5 ± 13.8 years, submitted to the cone reconstruction technique, obtained in the preoperative, early postoperative (EPO) and long-term (LPO) periods.
Results: There were two in-hospital deaths (3.8%) and two more during the follow-up. Mean functional class of pre-operative heart failure improved from 2.2 to 1.2 after 57 months of mean follow up of 97% of patients (p <0.001). The mean degree of preoperative tricuspid regurgitation decreased from 3.6 to 1.6 in the EPO (p <0.001), remaining at 1.9 in LPO period (p> 0.05). The indexed RV functional area increased from 8.53 ± 7.02 cm²/m² preoperatively to 21.01 ± 6.87 cm²/m² in the EPO (p <0.001) and remained unchanged at 20.28 ± 5.26 cm²/m² in LPO period (p> 0.05). The mean cardiothoracic ratio was decreased from 0.66 ± 0.09 to 0.54 ± 0.06 (p <0.001) in the long term.
Conclusion: The cone technique showed low in-hospital mortality, resulting in an effective and long-lasting repair of tricuspid regurgitation, restoring the functional area of the right ventricle and allowing reverse remodeling of the heart and clinical improvement in most patients in the long term.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/s0066-782x2011005000084 | DOI Listing |
Int J Comput Assist Radiol Surg
January 2025
Department of Medical Biophysics, University of Toronto, Toronto, Canada.
Purpose: During endovascular revascularization interventions for peripheral arterial disease, the standard modality of X-ray fluoroscopy (XRF) used for image guidance is limited in visualizing distal segments of infrapopliteal vessels. To enhance visualization of arteries, an image registration technique was developed to align pre-acquired computed tomography (CT) angiography images and to create fusion images highlighting arteries of interest.
Methods: X-ray image metadata capturing the position of the X-ray gantry initializes a multiscale iterative optimization process, which uses a local-variance masked normalized cross-correlation loss to rigidly align a digitally reconstructed radiograph (DRR) of the CT dataset with the target X-ray, using the edges of the fibula and tibia as the basis for alignment.
Phys Med
January 2025
Department of Physics "A. Pontremoli", University of Milan & INFN sez. Milano, Milano, Italy. Electronic address:
Purpose: This work aims at investigating, via in-silico evaluations, the noise properties of an innovative scanning geometry in cone-beam CT (CBCT): eCT. This scanning geometry substitutes each of the projections in CBCT with a series of collimated projections acquired over an oscillating scanning trajectory. The analysis focused on the impact of the number of the projections per period (PP) on the noise characteristics.
View Article and Find Full Text PDFPhys Med
January 2025
Department of Radiation Oncology, The Third Affiliated Hospital, Sun Yan-Sen University, Guangzhou 510630, China. Electronic address:
A preliminary study was conducted using electronic portal imaging device (EPID) based dose verification in pre-treatment and in vivo dose reconstruction modes for breast cancer intensity-modulated radiation therapy (IMRT) technique with known repositioning set-up errors. For 43 IMRT plans, the set-up errors were determined from 43 sets of EPID images and 258 sets of cone beam computed tomography images. In-house developed Edose software was used to reconstruct the dose distribution using the pre-treatment and on-treatment (in vivo) EPID acquired fluence maps.
View Article and Find Full Text PDFJ Forensic Odontostomatol
December 2024
Laboratory of Personal Identification and Forensic Morphology, Department of Health Sciences, University of Florence, Florence, Italy.
The age estimation of skeletal remains still represents a central issue not only for the reconstruction of the so-called "biological profile," but mostly for the palaeodemographic investigation. This research aims at verifying the feasibility of the adult age estimation method developed on living people by Pinchi et al. (2015 and 2018), for estimating the age at the death of 37 subjects from ancient populations found in two different Italian necropolis of archaeological interest (Mont'e Prama and Florence, X-IX century B.
View Article and Find Full Text PDFOral Maxillofac Surg
January 2025
Department of Orthodontics and Craniofacial Biology, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands.
Purpose: This study aimed to evaluate the dental and skeletal stability one year after Miniscrew-Assisted Rapid Palatal Expansion (MARPE) by using 3D image data.
Methods: Patients with transverse maxillary deficiency from the age of 16 onwards were enrolled consecutively in this prospective longitudinal cohort study. The MARPE appliance was digitally and individually designed and fabricated.