Limited weight bearing of the lower extremity is a commonly applied procedure in orthopaedic rehabilitation after reconstructive forefoot surgery, trauma surgery and joint replacement. The most frequent limitations are given as percentage of body weight (BW) and represent 10 or 50% BW. The extent of foot loading under these graduations of partial weight bearing has not yet been described in detail. The objective of this study was to investigate forces at the foot-sole interface, which occur under graduated limitations of weight bearing. Peak pressure, maximum force, pressure-time integral and force-time integral (Pedar Cable) were assessed for a total of three trials with 10 healthy individuals. The results from limited weight bearing with 10 or 50% BW as taught by an experienced physiotherapist with a bathroom scale were referred to results of a normal gait. The limitation of weight bearing to 10% BW was equal to a bisection of peak pressure and maximum force for the total foot. Halved BW left a remaining 82% of peak pressure and 59% of maximum force for the total foot. We concluded that weight-bearing limitations to 10 and 50% BW lead to discernible differences in foot loading and may be applied to graduate forces of the lower limb for rehabilitation purposes. Foot loading with partial weight bearing exerts the percentage of BW and should be monitored to avoid an exertion of strains on the lower limb.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MRR.0b013e3283498b25DOI Listing

Publication Analysis

Top Keywords

weight bearing
28
foot loading
16
partial weight
12
peak pressure
12
maximum force
12
graduations partial
8
weight
8
limited weight
8
pressure maximum
8
force total
8

Similar Publications

Introduction: Reconstruction for various regions of the foot and ankle in pediatric patients remains a challenging topic. This study presents the circumflex scapular artery perforator (CSAP) flap and its surgical refinements for addressing soft tissue defects in various regions of the foot and ankle in pediatrics.

Patients And Methods: Forty-seven patients underwent CSAP flap and its surgical refinements for the reconstruction of foot and ankle defects from 2010 to 2022.

View Article and Find Full Text PDF

Load-bearing capacity of an experimental dental implant made of Nb-1Zr.

J Mater Sci Mater Med

January 2025

Clinic of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.

Although implants have undergone a remarkable development over the past decades, modern implants still show complications that make the improvement of materials necessary. The presented study investigates the load-bearing capacity of an experimental dental implant made of a niobium alloy (Nb1Zr) compared to identical implants made of Ti6Al4V using chewing simulation for artificial aging. Eight implants each with an experimental design were manufactured from Nb1Zr and Ti6Al4V.

View Article and Find Full Text PDF

Background And Objective: A safe working trajectory is mandatory for spinal pathologies, especially in the midline, anterior to the spinal cord. For thoracic cerebrospinal fluid (CSF) leaks, we developed a minimally invasive keyhole fenestration. This study investigates the necessary bone removal for sufficient exposure of different leak types particularly regarding weight-bearing structures.

View Article and Find Full Text PDF

The unexpected PD-L1 suppression function of celery-derived extracellular vesicles improves lung cancer chemotherapy efficacy.

Extracell Vesicles Circ Nucl Acids

November 2024

State Key Laboratory of Systems Medicine for Cancer, Renji Hospital, School of Medicine and School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China.

The article explores celery-derived extracellular vesicles (CDEVs), characterized by high cellular uptake, low immunogenicity, and high stability, as a therapeutic strategy for antitumor nanomedicines. The methods employed in this study include cell experiments such as co-culture, Western Blot, and flow cytometry. experiments were conducted in C57BL/6 tumor-bearing mice subcutaneously injected with Lewis lung carcinoma (LLC) cells.

View Article and Find Full Text PDF

Three-step click assembly using trivalent platforms bearing azido, ethynyl, and fluorosulfonyl groups.

Chem Commun (Camb)

January 2025

Department of Biological Science and Technology, Faculty of Advanced Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku Tokyo 125-8585, Japan.

Divergent synthesis of triazoles was achieved using newly designed platform molecules possessing azide, alkyne, and fluorosulfonyl moieties. Consecutive conjugations by the sulfur(VI) fluoride exchange and following consecutive triazole formations allowed us to prepare a wide variety of bis(triazole)s by virtue of selective transformations. One-pot triple-click assembly of easily accessible modules led to the facile synthesis of middle-molecular-weight triazoles with various functional moieties.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!