Assessment of small volume ionization chambers as reference dosimeters in high-energy photon beams.

Phys Med Biol

CEA, LIST, Laboratoire National Henri Becquerel, 91191 Gif-sur-Yvette CEDEX, France.

Published: September 2011

LNE-LNHB is involved in a European project aiming at establishing absorbed dose-to-water standards for photon-radiation fields down to 2 × 2 cm². This requires the calibration of reference ionization chambers of small volume. Twenty-four ionization chambers of eight different types with volume ranging from 0.007 to 0.057 cm³ were tested in a ⁶⁰Co beam. For each chamber, two major characteristics were investigated: (1) the stability of the measured current as a function of the irradiation time under continuous irradiation. At LNE-LNHB, the variation of the current should be less than ±0.1% in comparison with its first value (over a 16 h irradiation time); (2) the variation of the ionization current with the applied polarizing voltage and polarity. Leakage currents were also measured. Results show that (1) every tested PTW (31015, 31016 and 31014) and Exradin A1SL chambers demonstrate a satisfying stability under irradiation. Other types of chambers have a stability complying with the stability criterion for some or none of them. (2) IBA CC01, IBA CC04 and Exradin A1SL show a proper response as a function of applied voltage for both polarities. PTW, Exradin A14SL and Exradin A16 do not. Only three types of chambers were deemed suitable as reference chambers according to LNE-LNHB requirements and specifications from McEwen (2010 Med. Phys. 37 2179-93): Exradin A1SL chambers (3/3), IBA CC04 (2/3) and IBA CC01 (1/3). The Exradin A1SL type with an applied polarizing voltage of 150 V was chosen as an LNE-LNHB reference chamber type in 2 × 2 cm² radiation fields.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/56/17/011DOI Listing

Publication Analysis

Top Keywords

exradin a1sl
16
ionization chambers
12
small volume
8
chambers
8
irradiation time
8
applied polarizing
8
polarizing voltage
8
a1sl chambers
8
types chambers
8
iba cc01
8

Similar Publications

Background: The newly available ZAP-X stereotactic radiosurgical system is designed for the treatment of intracranial lesions, with several unique features that include a self-shielding, gyroscopic gantry, wheel collimation, non-orthogonal kV imaging, short source-axis distance, and low-energy megavoltage beam. Systematic characterization of its radiation as well as other properties is imperative to ensure its safe and effective clinical application.

Purpose: To accurately determine the radiation output of the ZAP-X with a special focus on the smaller diameter cones and an aim to provide useful recommendations on quantification of small field dosimetry.

View Article and Find Full Text PDF

Suitability of novel 3D-printed and coated vessels for water calorimetry.

Med Phys

August 2024

Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada.

Background: In water calorimetry, absolute dose to water is determined by measuring radiation-induced temperature rises. In conventional water calorimeters, temperature detectors are housed in handmade glass vessels that are filled with high-purity water, thus mitigating radiation-induced exo/endothermic chemical reactions of impurities that would otherwise introduce additional heat gain/loss, known as heat defect. Being hand-crafted, these glass vessels may suffer from imperfections, have shape and design constraints, are often backordered, and can be prohibitively expensive.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to directly calculate [Formula: see text] correction factors for four cylindrical ICs for a 0.35 T MR-linac using the Monte Carlo (MC) method.

Methods: A previously-validated TOPAS/GEANT4 MC head model of the 0.

View Article and Find Full Text PDF

Background: The static magnetic field present in magnetic resonance (MR)-guided radiotherapy systems can influence dose deposition and charged particle collection in air-filled ionization chambers. Thus, accurately quantifying the effect of the magnetic field on ionization chamber response is critical for output calibration. Formalisms for reference dosimetry in a magnetic field have been proposed, whereby a magnetic field quality conversion factor k is defined to account for the combined effects of the magnetic field on the radiation detector.

View Article and Find Full Text PDF

Quantifying uncertainties associated with reference dosimetry in an MR-Linac.

J Appl Clin Med Phys

November 2023

Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada.

Background: Magnetic resonance (MR)-guided radiation therapy provides capabilities to utilize high-resolution and real-time MR imaging before and during treatment, which is critical for adaptive radiotherapy. This emerging modality has been promptly adopted in the clinic settings in advance of adaptations to reference dosimetry formalism that are needed to account for the presence of strong magnetic fields. In particular, the influence of magnetic field on the uncertainty of parameters in the reference dosimetry equation needs to be determined in order to fully characterize the uncertainty budget for reference dosimetry in MR-guided radiation therapy systems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!