A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High incidence of inaccurate stent placement in the treatment of coronary aorto-ostial disease. | LitMetric

Objectives: The purpose of this study was to evaluate the incidence of inaccurate stent positioning in the treatment of coronary aorto-ostial lesions.

Background: The percutaneous treatment of aorto-ostial disease is challenging, with a paucity of data describing the incidence of stent mispositioning.

Methods: We retrospectively reviewed the accuracy of stent positioning in 100 consecutive coronary aorto-ostial lesions. Using careful angiographic review, each stent placement was classified as "missed" (> 1 mm distal or proximal to the angiographically determined ostium) or "accurately" positioned.

Results: The true ostium was missed during stent placement in 54% of cases. In 52% of the misses, the stent was placed too proximally. This proximal miss was associated with an inability to coaxially re-engage the treated vessel in 93% of the cases. The stent was placed too distally in 48% of missed cases, resulting in a placement of one or more additional overlapping stents in 38% of those cases. Clinical follow-up (mean, 24.5 ± 12.9 months) was obtained in 98% of cases. Angiographic follow-up prompted by recurrent chest pain or ischemia was performed in 45/100 cases. There was a three-fold increase in restenosis and target lesion revascularization (TLR) among the cohort of patients with stent misplacement (26% and 23%, respectively) compared to those with accurate stent placement (9% and 6%, respectively; p = 0.02 for both restenosis and TLR).

Conclusions: Angiographically-guided stenting for coronary aorto-ostial disease leads to a high incidence of proximal and distal stent misplacement. Stent mispositioning is associated with significantly higher restenosis and clinically driven TLR compared to patients with accurate stent placement.

Download full-text PDF

Source

Publication Analysis

Top Keywords

stent placement
20
coronary aorto-ostial
16
stent
13
aorto-ostial disease
12
high incidence
8
incidence inaccurate
8
inaccurate stent
8
treatment coronary
8
stent positioning
8
stent misplacement
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!