Thin layer chromatography (TLC) is a technique that is commonly employed in the forensic drug analysis of pharmaceutical preparations. Detection is typically accomplished using various visualization spray reagents. Conventional gas chromatography-mass spectrometry (GC-MS) analysis is typically performed to confirm the TLC results. Depending on the drugs tested and the instrument conditions required, this confirmation can take up to an hour to complete. Direct analysis in real time (DART™) is an ionization source, coupled to an accurate-mass time-of-flight mass spectrometer that has the capability to ionize materials under ambient conditions. To streamline analysis, the combination of TLC with DART™ detection is proposed to screen and subsequently identify drug compounds, all from the same TLC plate. DART™ confirmations of TLC analyses take <10 min to complete and compare favorably to GC-MS in sensitivity and selectivity. This study validates the use of TLC-DART in the forensic identification of the components of several pharmaceutical preparations.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1556-4029.2011.01881.xDOI Listing

Publication Analysis

Top Keywords

thin layer
8
layer chromatography
8
forensic drug
8
drug analysis
8
analysis
5
tlc
5
validation thin
4
chromatography accutof-dart™
4
accutof-dart™ detection
4
detection forensic
4

Similar Publications

Comparison of ZnS(Ag) Scintillator and Proportional Counter Tube for Alpha Detection in Thin-Layer Chromatography.

Pharmaceuticals (Basel)

December 2024

Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technical University Dresden, Fetscherstr. 74, 01307 Dresden, Germany.

(1) : Targeted alpha therapy is an emerging field in nuclear medicine driven by two advantages: overcoming resistance in cancer-suffering patients to beta therapies and the practical application of lower activities of Pb- and Ac-labelled peptides to achieve the same doses compared to beta therapy due to the highly cytotoxic nature of alpha particles. However, quality control of the Pb/Ac-radiopharmaceuticals remains a challenge due to the low activity levels used for therapy (100 kBq/kg) and the formation of several free daughter nuclides immediately after the formulation of patient doses; (2) : The routine alpha detection on thin-layer chromatograms (TLC) of Pb- and Ac-labelled peptides using a MiniScanPRO+ scanner combined with an alpha detector head was compared with detection using an AR-2000 scanner equipped with an open proportional counter tube. Measurement time, resolution and validity were compared for both scanners; (3) : For Ac, the quality control values of the radiochemical purity (RCP) were within the acceptance criteria 2 h after TLC development, regardless of when the TLC probe was taken.

View Article and Find Full Text PDF

One of the challenging problems in the research and development of vibration sensors relates to the formation of Ohmic contacts for the removal of an electrical signal. In some cases, it is proposed to use arrays of carbon nanotubes (CNTs), which can serve as highly elastic electrode materials for vibration sensors. The purpose of this work is to study the effect of a current-collecting layer of CNTs grown over silicon on the properties of a lead zirconate titanate (PZT) film, which is frequently employed in mechanical vibration sensors or energy harvesters.

View Article and Find Full Text PDF

The global asphalt production growth rate exceeded 10% in the past decade, and over 90% of the world's road surfaces are generated from asphalt materials. Therefore, the issue of asphalt aging has been widely researched. In this study, the aging of asphalt thin films under various natural conditions was studied to prevent the distortion of indoor simulated aging and to prevent the extraction of asphalt samples from road surfaces from impacting the aged asphalt.

View Article and Find Full Text PDF

Calcium phosphates are often used for biomedical applications. Hydroxyapatite, for example, has a wide range of applications because it mimics the mineral component of natural bone. Widespread interest in the catalytic properties of ceria is due to its use in automotive catalytic converters.

View Article and Find Full Text PDF

We have proposed and developed a method for measuring the thermal conductivity of highly efficient thermal conductors. The measurement method was tested on pure metals with high thermal conductivity coefficients: aluminum (99.999 wt.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!