Freedom of rotation of selected overdenture attachments: an in vitro study.

J Prosthet Dent

Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, USA.

Published: August 2011

Statement Of Problem: Attachments for mandibular overdentures may not allow for adequate freedom of rotation.

Purpose: The purpose of this study was to subject 3 commonly used stud types of resilient attachments to rotation and to measure and compare the degree of rotation that occurs before the attachments bind.

Material And Methods: Three stud attachments (ERA, Locator Extended Range, O-Ring System) with their corresponding metal housings were evaluated, first for a single implant system and secondly for a 2-attachment parallel implant system for the mandibular arch. Both the manufacturers' most and least retentive components were tested in each system. In the Locator system, the medium retention (3 lbs) for the standard is the most retentive of the extended range. A total of 60 test specimens, 5 per group, were fabricated. The attachments were connected to a 115-mm rod and attached to a testing device composed of a base, implant analogs, and a vertical plate holding graph paper. A free-sliding plastic block, which supported the metal rod parallel to the base, was removed to release the rod. The distance the rod fell was photographed and input into a computer with software designed to measure linear movement. Three-way ANOVA with heteroscedasticity consistent standard errors was used for data analyses (α=.05).

Results: Significant differences found among the most retentive components showed that the Locator had a greater freedom of rotation than the ERA (P=.001). The most retentive components in all systems showed that 1 attachment had a greater freedom of rotation than 2 (P=.005). When testing the least retentive components, all systems were significantly different (P<.003), with the freedom of rotation ranking being O-Ring System > Locator Extended Range > ERA. For all 3 systems, the least retentive components showed the most freedom (P≤.008).

Conclusions: The least retentive components offer greater rotation than the most retentive components for all attachment systems tested and for both single and double attachments. Using the most retentive components, the Locator Extended Range attachment allows greater rotation than does the ERA for both single and double attachments. Using the least retentive components, the ORS attachment allows the most rotation and ERA the least for both single and double attachments. Using the most retentive components, one attachment allows greater rotation than does 2 attachments for the attachment systems evaluated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0022-3913(11)60099-1DOI Listing

Publication Analysis

Top Keywords

retentive components
40
extended range
16
freedom rotation
12
locator extended
12
rotation era
12
greater rotation
12
single double
12
double attachments
12
attachments retentive
12
attachment allows
12

Similar Publications

Ex situ conservation of plant genetic resources (PGR) plays a crucial role in sustainable growth and development, as highlighted by the Global Strategy for Plant Conservation (GSPC). Seed genebanks, a key component of ex situ conservation, have been instrumental in preserving plant diversity. However, challenges arise with the conservation of non-orthodox (recalcitrant and intermediate) seeds and vegetative tissues, which are not amenable to storage in traditional genebanks at temperatures of -20°C.

View Article and Find Full Text PDF

Separators are critical components of zinc-metal batteries (ZMBs). Despite their high ionic conductivity and excellent electrolyte retention, the widely used glass fiber (GF) membranes suffer from poor mechanical stability and cannot suppress dendrite growth, leading to rapid battery failure. Contrarily, polymer-based separators offer superior mechanical strength and facilitate more homogeneous zinc (Zn) deposition.

View Article and Find Full Text PDF

The influence of additives and modifiers on the chiral HPLC separation of the nicotine enantiomers using UV/Vis detection is discussed. Selected alcohols as modifiers and selected amines as additives were found to have a significant effect on the resolution and retention times of nicotine enantiomers even to the point of eliminating component elution. Systematic variations in the concentration of ethanol, methanol, and isopropanol, as modifiers, along with variations in the concentration of diethylamine, triethylamine, tributylamine, ethylenediamine, isopropylamine, as additives, revealed that the average resolution (R) of the nicotine enantiomers ranged from 2.

View Article and Find Full Text PDF

Objective: This study aimed to qualitatively study the main chemical components of apple peel in APORT, Kazakhstan, by ultra-performance liquid chromatography-quadrupole-time-of-flight mass spectrometry (UPLC-Q-TOF-MS/MS) and to compare the components of apple peels with different provenances.

Methods: An ACQUITY UPLC HSS T3 (100 mm × 2.1 mm, 1.

View Article and Find Full Text PDF

Background: Mentoring, advising, and coaching are essential components of resident education and professional development. Despite their importance, there is limited literature exploring how anesthesiology faculty perceive these practices and their role in supporting residents.

Objective: This study aims to investigate anesthesiology faculty perspectives on the significance, implantation strategies, and challenges associated with mentorship, advising, and coaching in resident education.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!