A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Supra acetabular bone mineral density measurements after hip resurfacing arthroplasty at short term follow up. | LitMetric

Implantation of a cementless press-fit acetabular cup during hip arthroplasty alters stress transfer to the periacetabular bone, resulting in stress shielding of cancellous bone and enhanced load transfer to cortical bone. Theoretically, the thicker, stiffer and larger acetabular cup of a hip resurfacing may increase periacetabular bone stress shielding. We attempted to assess the matter (at a minimum of 2 years after surgery) by measuring any difference in supra acetabular bone mineral density (BMD) between the side implanted with a thick monoblock cobalt-chromium (Co-Cr) acetabular component during hip resurfacing (HR) and the opposite non-operated side. We retrospectively recruited 44 patients who had undergone metal-on-metal hybrid hip resurfacing for unilateral osteoarthritis of the hip joint . BMD of the supra acetabular bone of both hips was measured using a dual energy X-ray absorptiometry (DEXA) scan. The BMD measured in Zone 2 was not different on the operated side (1.69 g/cm2 ± 0.48) compared with the non-operated side (1.70 g/cm2 ±0.49) (p=0.904). Contrary to our expectations, implantation of a monoblock Co-Cr acetabular component during HR did not cause significant stress-shielding of supra acetabular cancellous bone.

Download full-text PDF

Source
http://dx.doi.org/10.5301/HIP.2011.8573DOI Listing

Publication Analysis

Top Keywords

supra acetabular
16
hip resurfacing
16
acetabular bone
12
bone
8
bone mineral
8
mineral density
8
acetabular cup
8
cup hip
8
periacetabular bone
8
bone stress
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!