AI Article Synopsis

Article Abstract

Purpose: To present the short-term surgical outcomes of robotic-assisted sacrocolpopexy and sacrocervicopexy.

Methods: Between January 2009 and September 2010, 12 patients underwent robotic-assisted pelvic organ prolapse repair including six sacrocolpopexy and six sacrocervicopexy. Patients' demographics, surgical procedures, operative and postoperative complications, hospital stay, conversion to laparotomy, time data including all operative times and estimated blood loss (EBL) were recorded.

Results: All surgeries were completed robotically with no conversion to laparotomy. The average operative time for the robotic-assisted sacrocolpopexy (RASCP) was 150.5 ± 29.6 min (range 114-189) and the mean console time was calculated as 123.6 ± 34.2 min (range 84-166). The averages of the dissection and the suturation time were 34.8 ± 24.3 min (range 13-72) and 63.3 ± 21.8 min (range 28-95), respectively. The mean length of hospitalization was 2.8 ± 0.7 days (range 2-4) and the mean EBL was calculated as 12.5 ± 4.1 ml (range 10-20). There was one intraoperative complication. The mean age and body mass index of the patients underwent robotic-assisted sacrocervicopexy were 38.1 ± 6.5 years (29-47) and 28.4 ± 5.8 kg/m(2) (18.6-34.4), respectively. The mean operating times were calculated as follows: set-up time was 25.6 ± 4.0 min, docking time was 3 ± 0.8 min, dissection time was 28.6 ± 7.7 min, suturation time was 70.8 ± 10.9 min and console time was 123.1 ± 23.6 min. There were no recurrences during the follow-up period (12 months) in both groups of the patients.

Conclusion: The use of the robotic system during pelvic organ prolapse repair is feasible, safe and may support the surgeon during dissection and suturing at the level of sacral promontory.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00404-011-2032-5DOI Listing

Publication Analysis

Top Keywords

min range
16
pelvic organ
12
organ prolapse
12
time
9
min
9
robotic-assisted sacrocolpopexy
8
patients underwent
8
underwent robotic-assisted
8
prolapse repair
8
conversion laparotomy
8

Similar Publications

The pathogenic potential of airborne particles carrying the SARS-CoV-2 viral genome was examined by considering the size distribution of airborne particles at given distances from the respiratory zone of an infected patient after coughing or sneezing with a focus on time, temperature, and relative humidity. The results show an association between the size distribution of airborne particles, particularly PM and PM, and the presence of viral genome in different stations affected by the distance from the respiratory zone and the passage of time. The correlation with time was strong with all the dependent factors except PM.

View Article and Find Full Text PDF

Based on nitrogen and phosphorus co-doped carbon dots (NP-CDs), a direct, quick, and selective sensing probe for fluorometric detection of rutin has been developed. Utilizing ethylene diamine tetra acetic acid (EDTA) as a carbon and nitrogen source and diammonium hydrogen phosphate (NH)HPO as a nitrogen and phosphorus source. The NP-CDs were synthesized in less than 3 min with a straightforward one-step microwave pyrolysis process with a high quantum yield (63.

View Article and Find Full Text PDF

Cardiopulmonary exercise testing as a prognosis-assessing tool in heart failure with preserved ejection fraction.

ESC Heart Fail

January 2025

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Berlin, Germany.

Aims: Patients with heart failure with preserved ejection fraction represent half of the heart failure patients nowadays, an at least steady trend due to the aging of the population. We investigated whether the parameters obtained from cardiopulmonary exercise testing (CPET) correlated with the prognosis of these patients. This prospective observational cohort study assesses the relationship between the CPET parameters peakVO and VE/VCO slope and the number of heart failure hospitalizations or cardiovascular death of these patients.

View Article and Find Full Text PDF

Purpose: The present review investigates the responses of heart rate variability indices following high-intensity interval aerobic exercise, comparing it with moderate-intensity continuous exercise in adults, with the aim of informing clinical practice.

Methods: Searches were conducted in four databases until March 2023. Eligible studies included randomized controlled trials that assessed heart rate variability indices such as the standard deviation of normal-to-normal heartbeat intervals (SDNN), the root mean square of successive differences (RMSSD), the proportion of the number of pairs of successive normal-to-normal (NN or R-R) intervals that differ by more than 50 ms (NN50) divided by the total number of NN intervals (pNN50), power in high frequency range (HF), power in low frequency range (LF), and LF/HF before and after high-intensity interval and moderate-intensity continuous aerobic exercise.

View Article and Find Full Text PDF

Arieli has previously demonstrated that the exposure metric K could be used to predict pulmonary oxygen toxicity (POT) based on changes in Vital Capacity (VC). Our previous findings indicate that the Equivalent Surface Oxygen Time (ESOT) allows the estimation of POT without loss of accuracy compared to K. In this work, we have further investigated POT recovery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!