We fabricated a nanowire-based gas sensor using a simple method of growing SnO(2) nanowires bridging the gap between two pre-patterned Au catalysts, in which the electrical contacts to the nanowires are self-assembled during the synthesis of the nanowires. The gas sensing capability of this network-structured gas sensor was demonstrated using a diluted NO(2). The sensitivity, as a function of temperature, was highest at 200 °C and was determined to be 18 and 180 when the NO(2) concentration was 0.5 and 5 ppm, respectively. Our sensor showed higher sensitivity compared to different types of sensors including SnO(2) powder-based thin films, SnO(2) coating on carbon nanotubes or single/multiple SnO(2) nanobelts. The enhanced sensitivity was attributed to the additional modulation of the sensor resistance due to the potential barrier at nanowire/nanowire junctions as well as the surface depletion region of each nanowire.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0957-4484/19/9/095508DOI Listing

Publication Analysis

Top Keywords

gas sensor
12
sno2
5
sensor
5
novel fabrication
4
fabrication sno2
4
sno2 nanowire
4
gas
4
nanowire gas
4
sensor high
4
sensitivity
4

Similar Publications

electrochemical sensing of neurotransmitters, neuromodulators, and metabolites plays a critical role in real-time monitoring of various physiological or psychological processes in the central nervous system. Currently, advanced electrochemical biosensors and technologies have been emerging as prominent ways to meet the surging requirements of monitoring of neurotransmitters and neuromodulators ranging from single cells to brain slices, even the entire brain. This review introduces the fundamental working principles and summarizes the achievements of electrochemical biosensing technologies including voltammetry, amperometry, potentiometry, field-effect transistor (FET), and organic electrochemical transistor (OECT).

View Article and Find Full Text PDF

One of the leading challenges in Water Resource Recovery Facility monitoring and control is the poor data quality and sensor consistency due to the tough and complex circumstances of the process operation. This paper presents a new principal component analysis fault detection approach for the nitrate and nitrite concentration sensor based on Water Resource Recovery Facility measurements, together with the Fisher Discriminant Analysis identification of fault types. Five malfunction cases were considered: constant additive error, ramp changing error in time, incorrect amplification error, random additive error, and unchanging sensor value error.

View Article and Find Full Text PDF

Titanium nitride sensor for selective NO detection.

Nat Commun

January 2025

School of Environmental Science and Technology, Dalian University of Technology, Dalian, China.

Efficient detection methods are needed to monitor nitrogen dioxide (NO), a major NO pollutant from fossil fuel combustion that poses significant threats to both ecology and human health. Current NO detection technologies face limitations in stability and selectivity. Here, we present a transition metal nitride sensor that exhibits exceptional selectivity for NO, demonstrating a sensitivity 30 times greater than that of the strongest interfering gas, NO.

View Article and Find Full Text PDF

Visual, sensitive, and selective detection of carcinogenic substances is highly desired in portable health protection and practical medicine production. However, achieving this goal presents significant challenges with the traditional single-mode sensors reported so far, as they have limited sensing mechanisms and provide only a single output signal. Here, we report an effective optical and electrical dual-mode sensor for the visual, sensitive, and selective detection of -nitrosodiethylamine (NDEA), a typical volatile carcinogenic substance, leveraging the synergy of ionic liquid-doped liquid crystals (IL-LC).

View Article and Find Full Text PDF

Insight into human physiology is key to maintaining diver safety in underwater operational environments. Numerous hazardous physiological phenomena can occur during the descent, the time at depth, the ascent, and the hours after a dive that can have enduring consequences. While safety measures and strict adherence to dive protocols make these events uncommon, diving disorders still occur, often with insufficient understanding of the factors that triggered the event.