Background: Treatment of coronary bifurcation lesions remains challenging, beyond the introduction of drug eluting stents. Dedicated stent systems are available to improve the technical approach to the treatment of these lesions. However dedicated stent systems have so far not reduced the incidence of stent restenosis. The aim of this study was to assess the expansion of the Multi-Link (ML) Frontier™ stent in human and porcine coronary arteries to provide the cardiologist with useful in-vitro information for stent implantation and selection.
Methodology/principal Findings: Nine ML Frontier™ stents were implanted in seven human autopsy heart samples with known coronary artery disease and five ML Frontier™ stents were implanted in five porcine hearts. Proximal, distal and side branch diameters (PD, DD, SBD, respectively), corresponding opening areas (PA, DA, SBA) and the mean stent length (L) were assessed by micro-computed tomography (micro-CT). PD and PA were significantly smaller in human autopsy heart samples than in porcine heart samples (3.54±0.47 mm vs. 4.04±0.22 mm, p = 0.048; 10.00±2.42 mm(2) vs. 12.84±1.38 mm(2), p = 0.034, respectively) and than those given by the manufacturer (3.54±0.47 mm vs. 4.03 mm, p = 0.014). L was smaller in human autopsy heart samples than in porcine heart samples, although data did not reach significance (16.66±1.30 mm vs. 17.30±0.51 mm, p = 0.32), and significantly smaller than that given by the manufacturer (16.66±1.30 mm vs. 18 mm, p = 0.015).
Conclusions/significance: Micro-CT is a feasible tool for exact surveying of dedicated stent systems and could make a contribution to the development of these devices. The proximal diameter and proximal area of the stent system were considerably smaller in human autopsy heart samples than in porcine heart samples and than those given by the manufacturer. Special consideration should be given to the stent deployment procedure (and to the follow-up) of dedicated stent systems, considering final intravascular ultrasound or optical coherence tomography to visualize (and if necessary optimize) stent expansion.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3140974 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0021778 | PLOS |
Int J Behav Nutr Phys Act
January 2025
Global Centre for Preventive Health and Nutrition, Institute for Health Transformation, School of Health and Social Development, Faculty of Health, Deakin University, Burwood, VIC, 3125, Australia.
Background: Effective evidence-based physical activity and nutrition interventions to prevent overweight and obesity and support healthy child development need to be sustained within Early Childhood Education and Care (ECEC) services. Despite this, little is known about factors that influence sustainability of these programs in ECEC settings. Therefore, the aim of this study was to describe the factors related to sustainability of physical activity and nutrition interventions in ECEC settings and examine their association with ECEC service characteristics.
View Article and Find Full Text PDFClin Proteomics
January 2025
Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo A. Gemelli, 1, 00168, Rome, Italy.
Our objective is to determine the protein and complements constituents of Cord blood Platelet-rich plasma (CB-PRP), based on the hypothesis that it contains beneficial components capable of arresting or potentially decelerating the advancement of atrophic age-related macular degeneration (dry-AMD), with the support of radiomics. Two distinct pools of CB-PRP were assessed, each pool obtained from a total of 15 umbilical cord-blood donors. One aliquot of each pool respectively was subjected to proteomic analysis in order to enhance the significance of our findings, by identifying proteins that are shared between the two sample pools and gaining insights into the pathways they are associated with.
View Article and Find Full Text PDFJ Mol Cell Cardiol
December 2024
A.I.Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland; Heart Centre and Gene Therapy Unit, Kuopio University Hospital, Kuopio, Finland. Electronic address:
Background: Coronary stenting operations have become the main option for the treatment of coronary heart disease. Vessel recovery after stenting has emerged as a critical factor in reducing possible complications. In this study, we evaluated the feasibility, safety and efficacy of locally administered intraluminal gene therapy delivered using a specialized infusion balloon catheter.
View Article and Find Full Text PDFBMJ Open
January 2025
Bio Heart Cardiovascular Diseases Research Group, Bellvitge Institute for Biomedical Research, L'Hospitalet de Llobregat, Barcelona, Spain.
Introduction: Chronic hand ischaemia may affect some haemodialysis patients with an arteriovenous fistula (AVF) or graft (AVG), a condition known as haemodialysis access-induced distal ischaemia (HAIDI). Duplex ultrasonography (DUS) can provide comprehensive insights into anatomical and perfusion properties, and measuring the hand acceleration time (HAT) has been demonstrated to be sensitive within the framework of chronic upper limb ischaemia.
Methods And Analysis: This single-centre, prospective cohort study will involve adult end-stage renal disease (ESRD) patients requiring either AVF or AVG for haemodialysis.
Clin Chem Lab Med
January 2025
Canadian Microbiology Proficiency Testing Program (CMPT), Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada.
Providers of external quality assessment (EQA) programs evaluate data or information obtained and reported by participant laboratories using their routine procedures to examine properties or measurands in samples provided for this purpose. EQA samples must offer participants an equal chance to obtain accurate results, while being designed to provide results in clinically relevant ranges. It is the responsibility of the EQA provider to meet the necessary requirements for homogeneity, stability and some other properties of the EQA items in order to offer participants a fair, reliable and technically interesting EQA experience.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!