Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Designing a rapid, reliable and sensitive assay for detection of hepatitis B virus (HBV) variants by real-time PCR is challenging at best. A recent approach for quantifying the viral load using a sensitive fluorescent principle was brushed in this study.
Materials And Methods: : A total of 250 samples were collected from the outpatient unit, CLRD. Complete Human HBVDNA sequences (n = 944) were selected from the National Centre for Biotechnology Information (NCBI), primers and probes were designed and synthesized from the core, surface, and x region. Real-time based quantification was carried out using a standard kit and in-house generated standards and RT-PCR protocols.
Results And Discussion: The standard calibration curve was generated by using serial dilution 10(2) to 10(8). The calibration curve was linear in a range from 10(2) to 10(8) copies/ml, with an R(2) value of 0.999. Reproducibility as measured by dual testing of triplicates of serum samples was acceptable, with coefficients of variation at 6.5%, 7.5%, and 10.5%. Our results showed that amplification performance was good in the case of the x-region-based design (98%). Out of 100 negative samples screened by enzyme linked immunosorbent assay and the standard RT-PCR kit, one sample was detected as positive with the in-house developed RT-PCR assay, the positivity of the sample was confirmed by sequencing the amplified product, NCBI accession EU684022.
Conclusion: This assay is reproducible showing limited inter- and intra-assay variability. We demonstrate that the results of our assay correlated well with the standard kit for the HBV viral load monitor.