Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Laparoendoscopic single-site donor nephrectomy (LESS-DN) is a procedure in evolution. Currently described techniques utilize single port access devices and articulating, flexible, and bent working instruments. We describe a modified technique of transumbilical LESS-DN with conventional laparoscopic instruments in five kidney donors.
Materials And Methods: Three standard laparoscopic ports (10 mm × 1, 5 mm × 2) were placed through a 4.5 cm vertical transumbilical incision. A 10 mm 45°, long bariatric lens (Karl Storz) was used. Renal mobilization was performed using conventional rigid laparoscopy instruments. A port closure needle loaded with a blunt plastic needle cap was used for traction. After hilar clamping, an incision was made connecting the three ports, and the kidney was extracted using a preplaced suture over the lower pole fat. All data were prospectively recorded.
Results: LESS-DN was performed successfully in all five patients. The mean operative time was 157.2 minutes (range, 134-184) and the mean warm ischemia time was 3.2 minutes (range, 3-4). All donors were discharged on postoperative day 3 and were able to resume normal physical activity by 2 weeks after the procedure. All donors had an excellent cosmetic outcome. The mean serum creatinine (recipient) at discharge was 1.14 mg% (range, 0.9-1.4).
Conclusions: Transumbilical LESS-DN can be cost-effectively performed using conventional laparoscopy instruments and without the need for a single port access device. Warm ischemia times with this technique are comparable with that during conventional multiport laparoscopic donor nephrectomy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3142826 | PMC |
http://dx.doi.org/10.4103/0970-1591.82834 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!