Objectives: Evaluation of the effect of different span length and preparation designs on the fracture load of tooth-implant-supported fixed dental prostheses (TIFDPs) manufactured from yttrium-stabilized zirconia frameworks.
Material And Methods: Forty-eight TIFDPs were manufactured using a CAD/CAM system and veneered with a press ceramic. Rigidly mounted implants (SLA, diameter 4.1 mm, length 10 mm) in the molar region with a titanium abutment were embedded in PMMA bases pairwise with premolars. All premolars were covered with heat-shrink tubing to simulate physiological tooth mobility. Six different test groups were prepared (a) differing in the preparation design of the premolar (inlay [i]; crown [c]), (b) the material of the premolar (metal [m]; natural human [h]) and (c) the length of the TIFDPs (3-unit [3]; 4-unit [4]). All TIFDPs underwent thermomechanical loading (TCML) (10,000 × 6.5°/60°; 6 × 10(5) × 50 N). The load to fracture (N) was measured and fracture sites were evaluated macroscopically.
Results: None of the restorations failed during TCML. The mean fracture loads (standard deviations) were 1,522 N (249) for the 3-unit, inlay-retained TIFDPs on a metal abutment tooth (3-im), 1,910 N (165) for the 3-cm group, 1,049 N (183) for group 4-im, 1,274 N (282) for group 4-cm, 1,229 N (174) for group 4-ih and 911 N (205) for group 4-ch. Initial damages within the veneering ceramic occurred before the final failure of the restoration. The corresponding loads were 24-52% lower than the fracture load values.
Conclusions: All restorations tested could withstand the mastication forces expected. Fracture-load values for 3- and 4-unit inlay-crown and crown-crown-retained TIFDPs should spur further clinical investigation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1600-0501.2011.02191.x | DOI Listing |
Cells
December 2024
AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland.
In the context of bone fractures, the influence of the mechanical environment on the healing outcome is widely accepted, while its influence at the cellular level is still poorly understood. This study explores the influence of mechanical load on naïve mesenchymal stem cell (MSC) differentiation, focusing on hypertrophic chondrocyte differentiation. Unlike primary bone healing, which involves the direct differentiation of MSCs into bone-forming cells, endochondral ossification uses an intermediate cartilage template that remodels into bone.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Department of Sports Orthopaedics, Klinikum rechts der Isar (Technical University of Munich), Ismaninger Straße 22, 81675, Munich, Germany.
Purpose: This study aims to describe a fixation technique for coronoid fractures using suture buttons, and to biomechanically evaluate this technique in comparison to screw fixation as a time-zero pilot study.
Methods: An O'Driscoll type 2 anteromedial coronoid facet (AMCF) fracture was simulated in 20 fresh-frozen human elbows. The specimens were randomized into two groups and fracture fixation was performed with either a suture button system or a 3.
Clin Oral Investig
January 2025
Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Zurich, Switzerland.
Objectives: To compare the impact of intaglio surface treatments - airborne particle abrasion and hydrofluoric acid (HF) etching - of feldspar ceramic (FEL) crowns on the fracture load (FL) and to investigate the effects of abutment materials and artificial aging. The aim was to assess whether etching could be replaced by an alternative surface roughening method.
Materials And Methods: FEL crowns had their intaglio surfaces either abraded (25 µm AlO, 0.
J Dent
January 2025
Senior Research and Teaching Assistant, Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland. Electronic address:
Objectives: A new abutment-free implant connection allows for direct screwing of FDPs on implants to avoid complications caused by cement rests or screw loosening, which may affect to screw torque and load distribution. The objective of this study was to test the initial (Fi) and final failure (Ff) loads and torque changes of abutment-free monolithic zirconia CAD-CAM fixed dental prostheses (FDPs) compared to titanium FDPs on different abutment designs.
Methods: Three-unit screw-retained FDPs (n=50) on two implants (n=100) were divided into groups (n=10) based on the implant-abutment connection and material of the supra-structure: (1) abutment-free monolithic CAD-CAM zirconia FDP (Abut-free-Zr), (2) abutment-free veneered titanium FDPs (Abut-free-Ti), (3) monolithic zirconia FDPs with titanium base abutments (Zr-Ti-Base), (4) monolithic zirconia FDPs on multi-unit abutments (Zr-MU), (5) veneered titanium FDP on multi-unit abutments (Ti-MU).
J Prosthodont
January 2025
Department of Restorative Dental Science, College of Dentistry, University of Ha'il, Ha'il, Saudi Arabia.
Purpose: To investigate how varying ferrule heights and the number of glass fiber posts affect fracture resistance and behavior of endodontically treated maxillary first premolars with substantial loss of tooth structure.
Materials And Methods: Twenty-four extracted endodontically treated human maxillary first premolars were divided into three groups (n = 8) based on ferrule height and post number. The groups were as follows: premolars of 2 mm ferrule height that were restored with single posts (control group), premolars of 0.