A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A titanium expandable pedicle screw improves initial pullout strength as compared with standard pedicle screws. | LitMetric

Background Context: Pedicle screws are now standard for spinal arthrodesis as they provide three-column spinal stabilization. Decreased vertebral body bone density because of aging reduces the stability of the bone-screw interface, potentially increasing screw pullout or pseudarthrosis. Modifications to standard pedicle screw designs to improve screw stabilization may help to compensate for the detrimental effects of decreased vertebral bone density.

Purpose: To evaluate differences in initial pullout strength of an expandable titanium pedicle screw as compared with a standard titanium pedicle screw.

Study Design: In vitro human cadaveric biomechanical investigation.

Methods: Fresh thoracolumbar spines from four human cadavers were imaged using quantitative computed tomography to obtain standard lumbar osteoporosis (Dual-energy X-ray absorptiometry [DXA]) T scores. Six bodies were sectioned per spine, and standard titanium 6.5-mm diameter pedicle screws and expandable 6.5-mm diameter titanium screws (maximum expanded diameter=10 mm) were randomized to right and left sides. Screw testing, in axial pullout at 25 mm/min, was randomized to reduce the effects of testing order. Data for stiffness (N/mm), yield load (N), ultimate load (N), and energy (N mm) (area under the load-displacement curve) were analyzed using a one-way analysis of variance (p<.05).

Results: Lumbar DXA scores averaged -3.6. There were no statistical differences between screw types for stiffness. Yield load was not statistically different between groups, although the expandable screw yield load was nearly 25% greater than that of the standard screw. Ultimate load was found to be statistically greater (∼30%) for the expandable screw compared with the standard screw (p<.05). The energy required to cause bone-implant failure was also statistically greater for the expandable screw compared with the standard screw (p<.0001).

Conclusions: Expandable titanium pedicle screws demonstrated improved screw pullout stability compared with standard titanium screws in osteopenic or osteoporotic bone. Further studies are warranted examining other loading methods to evaluate the stability provided by an expandable pedicle screw.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.spinee.2011.06.006DOI Listing

Publication Analysis

Top Keywords

pedicle screw
12
pedicle screws
12
initial pullout
8
pullout strength
8
compared standard
8
standard pedicle
8
decreased vertebral
8
titanium pedicle
8
standard titanium
8
65-mm diameter
8