A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery? | LitMetric

Objectives: Flexible bronchoscopy is recommended to confirm correct placement of double-lumen tubes used for thoracic anesthesia. However, there is still controversy over routine bronchoscopic confirmation of their position. This study aimed to verify the usefulness of flexible bronchoscopy for confirming the position of double-lumen tubes after blind intubation.

Methods: During a 9-month period, consecutive patients undergoing elective oncologic thoracic surgery were prospectively enrolled in the study. All patients were intubated with a left disposable polyvinyl chloride double-lumen tube. Immediately after intubation, clinical verification was made by the anesthesiologist. Then, the endoscopist performed flexible bronchoscopy with a 2.8-mm diameter Olympus(®) video bronchoscope, and verified the position of the double-lumen tube, before positioning the patient. The double-lumen tube was in optimal position, if the bronchial cuff was immediately below the tracheal carina, and there was a clear view of the left subcarina, with unobstructed left upper and lower bronchi. Misplacement of the double-lumen tube was diagnosed when the tube had to be moved (in or out) for more than 0.5 cm to correct its position. Critical malposition meant a double-lumen tube dislocated in the trachea or in the right bronchi, requiring immediate re-intubation under bronchoscopic guidance.

Results: A total of 144 patients (44 women (42%) and 60 men (58%), with a mean age of 51 years (range 25-77 years)) were enrolled in the study. Surgical procedures included 37 right-sided and 31 left-sided thoracotomies, 22 video-assisted thoracoscopic surgeries (VATSs) (16 right-sided and six left-sided), one median sternotomy, six mediastinotomies, and seven miscellaneous procedures. In 66 (63%, 95% confidence interval 53.2-71.8%) cases, there was complete agreement between the anesthesiologist and the endoscopist. The latter diagnosed misplacement of the double-lumen tube in 33 (32%, 95% confidence interval 22.8-40.7%) patients and critical malposition in five (5%, 95% confidence interval 0.7-8.9%) cases.

Conclusions: After blind intubation, 37% of double-lumen tubes required repositioning by means of flexible bronchoscopy, despite positive evaluation made by the anesthesiologist. Our data suggests that initial bronchoscopic assessment should be made with the patient still in the supine position, and confirms that flexible bronchoscopy is useful in verifying the correct position of double-lumen tubes or adjusting possible misplacements, before starting thoracic surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejcts.2011.01.070DOI Listing

Publication Analysis

Top Keywords

flexible bronchoscopy
24
double-lumen tube
24
double-lumen tubes
20
position double-lumen
16
95% confidence
12
confidence interval
12
double-lumen
11
position
8
tubes thoracic
8
thoracic surgery
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!