A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Zwitterionic-type hydrophilic interaction nano-liquid chromatography of complex and high mannose glycans coupled with electrospray ionisation high resolution time of flight mass spectrometry. | LitMetric

In this study we describe a new method for rapid and sensitive analysis of reduced high mannose and complex glycans using zwitterionic-type hydrophilic interaction nano-liquid chromatography (nano ZIC-HILIC, 75 μm I.D.×150 mm) coupled with high resolution nanoelectrospray ionisation time of flight mass spectrometry (nano ESI-TOF-MS). The retention of neutral glycans increases with increasing molecular weight and is higher for high mannose glycans than for complex-type glycans. The selectivity of ZIC-HILIC for sialylated glycans differs from that for the neutral glycans and is believed to involve electrostatic repulsion; therefore, charged glycans are eluted earlier than neutral glycans with comparable molecular weight. Due to the improved sensitivity achieved by employing a ZIC-HILIC nano-column, a range of less common complex glycans has been studied and the high resolution mass spectrometry enabled confirmation of glycan composition for the proposed structures. Good sensitivity for glycans was achieved without prior fluorescent labelling, and the time of the analysis was significantly reduced compared to the separation of glycans on a conventional-size column. The proposed method offers a fast and sensitive approach for glycan profiling applied to analysis of biopharmaceuticals.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2011.07.006DOI Listing

Publication Analysis

Top Keywords

high mannose
12
glycans
12
high resolution
12
mass spectrometry
12
neutral glycans
12
zwitterionic-type hydrophilic
8
hydrophilic interaction
8
interaction nano-liquid
8
nano-liquid chromatography
8
mannose glycans
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!