A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with (198)Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) μg L(-1) could be performed with uncertainty amplification factors <2. A limit of quantification of 0.03 μg L(-1) was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were <10% at added concentration levels of 0.14 μg L(-1), 0.35 μg L(-1) and 2.8 μg L(-1), with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; <0.03-0.19) μg L(-1). This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2011.06.012 | DOI Listing |
Nutrients
January 2025
Department of Nutrition, University of Applied Sciences Münster (FH), 48149 Münster, Germany.
Rationale: The dietary components choline, betaine, and L-carnitine are converted by intestinal microbiota into the molecule trimethylamine (TMA). In the human liver, hepatic flavin-containing monooxygenase 3 oxidizes TMA to trimethylamine-N-oxide (TMAO). TMAO is considered a candidate marker for the risk of cardiovascular disease.
View Article and Find Full Text PDFChildren (Basel)
January 2025
Division of Neonatology, Department of Pediatrics, Emory University and Children's Healthcare of Atlanta, Atlanta, GA 30322, USA.
In recent years, significant advancements in respiratory and nutritional care have markedly improved the survival rates of preterm infants and enhanced long-term health outcomes. Despite these improvements, emerging research highlights the lasting impacts of early growth patterns on an individual's health trajectory. Adults born prematurely face a higher incidence of health issues related to their early birth.
View Article and Find Full Text PDFFood Chem X
January 2025
Institute of Nutrition, Mahidol University, Salaya, Phuthamonthon, Nakhon Pathom 73170, Thailand.
This study sought to validate the external calibration curve (CAL) method for iodine analysis in 26 selected foods and then to compare the test result with the isotope dilution mass spectrometry (IDMS). Iodine was extracted by tetramethylammonium hydroxide (TMAH) and determined by ICP-MS using CAL and IDMS methods. The results showed that iodine determination using the IDMS method had higher precision than the CAL method (LOD of the method were 0.
View Article and Find Full Text PDFJ Phys Chem Lett
January 2025
Molecular Spectroscopy Laboratory, RIKEN, 2-1 Hirosawa, Wako 351-0198, Japan.
Elucidation of the vibrational relaxation process of interfacial water is indispensable for understanding energy dissipation at the aqueous interface. In this study, the vibrational relaxation dynamics of the hydrogen-bonded OH (HB OH) stretch vibration was investigated at the air/isotopically diluted water (HOD-DO) interface by time-resolved heterodyne-detected vibrational sum frequency generation (TR-HD-VSFG) spectroscopy. We observed the temporal change of the excited-state band ( = 1 → 2 transition), which enables a reliable determination of the time of interfacial water.
View Article and Find Full Text PDFJ Nutr
January 2025
Department of Nutritional Sciences, The Pennsylvania State University, University Park, PA, USA.
Background: Retinol isotope dilution (RID) equations are used to predict vitamin A total body stores (TBS). Including population-based ("super-subject") modeling with RID provides group-specific values for the equation coefficients.
Objectives: Objective was to test an approach that would accommodate a limited super-subject sample size without compromising accuracy in RID predictions of TBS.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!