AI Article Synopsis

Article Abstract

The rapid detection of carriage of Streptococcus pneumoniae could assist in the management of pneumococcal infection, such as acute otitis media. We evaluated the reliability of the Binax NOW test in the exclusion and detection of pneumococcal carriage by nasal samples from 139 children and using nasopharyngeal samples from 250 children (aged 6-35 months) with respiratory infection with or without acute otitis media. The Binax NOW test results were compared with culture-based detection of carriage of S. pneumoniae. The Binax NOW test from the nasal samples had a sensitivity of 95%, a specificity of 78%, and the positive and negative predictive values were 83 and 93%, respectively; and for the nasopharyngeal samples the corresponding numbers were 88%, 95%, 96%, and 87%. When rapid knowledge of the carriage status of S. pneumoniae is needed, the Binax NOW test is a reliable method for the exclusion of carriage using nasal sampling, and in the detection of carriage using nasopharyngeal sampling.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10096-011-1361-4DOI Listing

Publication Analysis

Top Keywords

binax test
20
detection carriage
12
streptococcus pneumoniae
8
test nasal
8
infection acute
8
acute otitis
8
otitis media
8
carriage nasal
8
nasal samples
8
nasopharyngeal samples
8

Similar Publications

Implementation of Rapid COVID-19 Testing in Criminal Justice Residential Reentry Sites.

J Correct Health Care

October 2024

Department of Medicine, Division of Geographic Medicine and Infectious Diseases, Tufts Medical Center, Boston, Massachusetts, USA.

The goal was to study the implementation of rapid BINAX COVID-19 testing at criminal justice reentry sites, focusing on framework-guided implementation outcomes. We implemented rapid COVID-19 testing at nine reentry sites in four states (Massachusetts, New Hampshire, Rhode Island, and New York) and collected test results to measure the (1) adoptability and (2) implementability of COVID-19 testing at reentry sites. We collected data on the acceptability, appropriateness, and feasibility of the implementation of COVID-19 testing using an anonymous employee Qualtrics survey.

View Article and Find Full Text PDF

Background: A highly accurate, rapid, and low-cost COVID-19 test is essential for guiding isolation measures. To date, the most widely used tests are either nucleic acid amplification tests or antigen tests. The objective of this study is to further assess the diagnostic performance of the Binax-CoV2 rapid antigen test in comparison to the current gold standard reverse transcription quantitative polymerase chain reaction (RT-qPCR), with additional analysis of symptomatology and cycle threshold utility.

View Article and Find Full Text PDF

SARS-CoV-2 molecular testing and whole genome sequencing following RNA recovery from used BinaxNOW COVID-19 antigen self tests.

J Clin Virol

May 2023

Emory University Department of Medicine, Atlanta, GA, USA; Atlanta Center for Microsystems-Engineered Point-of-Care Technologies, Atlanta, GA, USA; Emory University Department of Pathology and Laboratory Medicine, Atlanta, GA, USA.

Widespread use of over-the-counter rapid diagnostic tests for SARS-CoV-2 has led to a decrease in availability of clinical samples for viral genomic surveillance. As an alternative sample source, we evaluated RNA isolated from BinaxNOW swabs stored at ambient temperature for SARS-CoV-2 rRT-PCR and full viral genome sequencing. 81 of 103 samples (78.

View Article and Find Full Text PDF

Coronavirus disease 2019 (COVID-19) convalescent plasma (CCP) use between October and December 2020 was characterized using the National Inpatient Sample database. CCP was administered in 18.0% of COVID-19-associated hospitalizations and was strongly associated with older age and increased disease severity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!