Radiography is used in medical practices based on the principles of justification and optimization. Patients' exposure doses should be kept as low as still allows for image quality that does not disturb the diagnostic processes. To optimize diagnostic radiological procedures, the international commission on radiological protection (ICRP) advocated the establishment of diagnosis reference levels (DRLs) in the new basic recommendation (Publication 103) in 2007 by stating that "The DRL should be expressed as a readily measurable patient-dose-related quantity for the specified procedure." In this context, a simple and standardized dosimetric method is needed to verify the adaptability of a radiation dose to the DRLs. As a measuring instrument that has good availability, high accuracy, and easy operability, we adopted the glass badge system, which has been used for individual exposure dose management. We evaluated the accuracy of the system as a tool of simplified dosimetry of diagnostic X-rays by comparing it to the standard dosimetry of an ionization chamber. In an energy range of 50 to 140 kV for X-ray exposure, the glass badge showed values within 7% of or closer to those measured by the standard ionization chamber. Moreover, the glass badge measurement was independent of the rectification modes of the X-ray tubes. In conclusion, glass badge measurement is feasible for verifying diagnostic X-ray doses in relation to DRLs and can be widely used in hospitals and clinics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.6009/jjrt.67.785 | DOI Listing |
Ir J Med Sci
December 2024
Cardiac Center, Tohoku Medical and Pharmaceutical University Hospital, Sendai, 983-8512, Japan.
Background: Radio frequency catheter ablation (RFCA), a treatment for arrhythmia, requires a long fluoroscopy time that increases the radiation exposure dose to the physician, particularly to the lens of the eye. It is recommended that a lens-specific dosimeter such as DOSIRIS® is used to measure the dose to the lens.
Aims: In this study, we investigated whether conventional glass badges can be used as an alternative to lens dosimeters.
Adv Mater
August 2024
National Engineering Lab for Textile Fiber Materials and Processing Technology, Zhejiang Sci-Tech University, Hangzhou, 310018, P. R. China.
Construction advanced fibers with high Faradic activity and conductivity are effective to realize high energy density with sufficient redox reactions for fiber-based electrochemical supercapacitors (FESCs), yet it is generally at the sacrifice of kinetics and structural stability. Here, a high-entropy doping strategy is proposed to develop high-energy-density FESCs based on high-entropy doped metal oxide@graphene fiber composite (HE-MO@GF). Due to the synergistic participation of multi-metal elements via high-entropy doping, the HE-MO@GF features abundant oxygen vacancies from introducing various low-valence metal ions, lattice distortions, and optimized electronic structure.
View Article and Find Full Text PDFInt J Biol Macromol
April 2024
School of Chemistry & Materials Engineering Fuyang Normal University, Fuyang, Anhui 236037, PR China.
The development of equipped bio-based epoxy materials has been gaining much attention recently. Nevertheless, finding the balance between the structure and properties of materials remains a significant challenge. In this work, cellulose-based epoxy (PHPCEP) with "soft" and "hard" cooperative structures was designed and demonstrated to endow bisphenol A diglycidyl ether (BADGE) with excellent toughness, heat resistance, mechanical strength, glass transition temperature, thermal stability, and solvent resistance.
View Article and Find Full Text PDFJ Radiol Prot
April 2024
Department of Quantum Medical Technology, Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80, Kodatsuno, Kanazawa, Ishikawa, Japan.
Vision badge is an eye lens dosimeter to measure(3). This study aimed to evaluate the basic characteristics of the Vision badge and its performance as an eye lens dosimeter for endoscopists by phantom study. Energy dependence was evaluated by changing the tube voltage to 50 kV (effective energy of 27.
View Article and Find Full Text PDFAnn Work Expo Health
March 2024
Department of Public Health, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, United States.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!