The purpose of this study is to evaluate the crosstalk effect on spin-echo (SE) images at 1.5 and 3 T MRI. We examined the influence of crosstalk by comparing the full width at half-maximum (FWHM) and slice profile of images of a wedge-shaped phantom for various slice gaps. We also assessed crosstalk effect in the brain by comparing image contrast among healthy volunteers (n=8). Among the subjects, the shapes of the slice profiles at 1.5 T were similar to those at 3 T for long repetition times (TRs); however, at shorter TRs, differences in slice profiles were observed among the subjects and were more apparent at 3 than at 1.5 T. The relative contrast between white matter and gray matter on T(1)-weighted images was lower at 3 than at 1.5 T. The crosstalk effect was strongest when the TR of the excitation pulse was short. The influence of the adjacent excitation pulse is important in the process of T(1) relaxation because T(1) values are greater at 3 T. In conclusion, the influence of crosstalk on SE T(1)-weighted images is greater at 3 than at 1.5 T.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.6009/jjrt.67.779 | DOI Listing |
Magn Reson Med
May 2024
Centre de Résonance Magnétique Biologique et Médicale, Aix-Marseille Universite, CNRS, Marseille, France.
Purpose: To investigate whether a T inter-slice variation could occur when a multi-slice multi-echo spin echo (MESE) sequence is used for image acquisition and to propose an enhanced method for reconstructing T maps that can effectively address and correct these variations.
Methods: Bloch simulations were performed accounting for the direct saturation effect to evaluate magnetization changes in multi-slice 2D MESE sequence. Experimental phantom scans were performed to validate these simulations.
J Med Life
June 2023
Department of Basic Sciences, College of Medicine, Hawler Medical University, Erbil, Iraq.
Magnetic resonance imaging (MRI) exams are essential for diagnostic procedures, but their lengthy duration and associated costs limit their accessibility. Shorter scan times would reduce expenses and allow for more MRI exams, expanding the range of diagnostic procedures. This study investigated technical factors that could decrease scan time without compromising image quality, including field-of-view (FOV), phase field of view, phase oversampling, cross-talk, brain MRI imaging resolution, and scan time.
View Article and Find Full Text PDFMagn Reson Med
December 2023
Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Purpose: To demonstrate T -weighted (single-echo) spin-echo (SE) imaging with near-optimal acquisition efficiency by applying SNR-efficient RF slice encoding and spiral readout.
Methods: A quadratic-phase (frequency swept) excitation RF pulse replaced the conventional excitation in T -weighted SE sequence to excite a thick slab that is internally spatially encoded by a variable phase along the slice direction. Highly overlapping slabs centered at every desired slice location were acquired in multiple passes, such that the entire imaging volume was excited by contiguous slabs in any given pass.
HSS J
July 2021
MRI Laboratory, Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA.
Hip arthroplasty is increasingly prevalent, and early detection of complications can improve outcomes. Quantitative magnetic resonance imaging (qMRI) methods using multi-acquisition variable-resonance image combination (MAVRIC) may allow for the assessment of soft tissues in close proximity to hip arthroplasty devices. : We sought to determine the clinical feasibility of MAVRIC-based T2 mapping as a qMRI approach for assessing synovial reactions in patients with a hip arthroplasty device.
View Article and Find Full Text PDFBiophys J
August 2021
2 J-PARC Center, Japan Atomic Energy Agency, Tokai, Ibaraki, Japan.
The flexible conformations of a multidomain protein are responsible for its biological functions. Although MurD, a 47-kDa protein that consists of three domains, sequentially changes its domain conformation from an open form to a closed form through a semiclosed form in its enzymatic reaction, the domain dynamics in each conformation remains unclear. In this study, we verify the conformational dynamics of MurD in the corresponding three states (apo and ATP- and inhibitor-bound states) with a combination of small-angle x-ray and neutron scattering (SAXS and SANS), dynamic light scattering (DLS), neutron backscattering (NBS), neutron spin echo (NSE) spectroscopy, and molecular dynamics (MD) simulations.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!