Objectives: This study was conceived to describe the evolution of aortic dimensions in patients with moderate post-stenotic ascending aorta dilation (50 to 59 mm) submitted to aortic valve replacement (AVR) alone.

Background: The appropriate treatment of post-stenotic ascending aorta dilation has been poorly investigated.

Methods: Ninety-three patients affected by severe isolated calcific aortic valve stenosis in the tricuspid aortic valve accompanied by moderate dilation of the ascending aorta (50 to 59 mm) were submitted to AVR only. All patients were followed for a mean of 14.7 ± 4.8 years by means of periodic clinical evaluations and echocardiography and tomography scans of the thorax.

Results: Operative mortality was 1.0% (1 patient). During the follow-up, 16 patients died and 2 had to be reoperated for valve dysfunction. No patients experienced acute aortic events (rupture, dissection, pseudoaneurysm), and no patient had to be reoperated on the aorta. There was not a substantial increase in aortic dimensions: mean aortic diameter was 57 ± 11 mm at the end of the follow-up versus 56 ± 02 mm pre-operatively (p = NS). The mean ascending aorta expansion rate was 0.3 ± 0.2 mm/year.

Conclusion: In the absence of connective tissue disorders, AVR alone is sufficient to prevent further aortic expansion in patients with moderate post-stenotic dilation of the ascending aorta. Aortic replacement can probably be reserved for patients with a long life expectancy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2011.03.040DOI Listing

Publication Analysis

Top Keywords

ascending aorta
24
aortic valve
16
post-stenotic ascending
12
aortic
11
aortic expansion
8
expansion rate
8
patients
8
aorta submitted
8
submitted aortic
8
valve replacement
8

Similar Publications

Background: Heart failure with preserved ejection fraction (HFpEF) is a high prevalence condition, with high rates of hospitalization and mortality. Arterial hypertension is the main risk factor for HFpEF. Among hypertensive patients, alterations in cardiac and vascular morphology identify hypertension-mediated organ damage (HMOD).

View Article and Find Full Text PDF

The mortality rate of postcardiotomy cardiogenic shock after cardiovascular surgery is quite high, and the only way to avoid this serious complication is to initiate a preemptive strategy during surgery. The Impella 5.5 device with the SmartAssist system (Abiomed) is mainly used to prevent or to treat cardiogenic shock in cardiac surgery, but it is not often used in aortic surgery.

View Article and Find Full Text PDF

Arch Bare Metal Stent Grafting in Type I Aortic Dissections After Hemiarch Repair.

Ann Thorac Surg Short Rep

December 2024

Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.

Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.

View Article and Find Full Text PDF

We report on a successful thoracic endovascular aortic repair for perigraft seroma (PGS) after ascending aorta replacement (AAR). An 82-year-old man underwent AAR. Two years after the operation, computed tomography showed a 75-mm PGS around the ascending aorta.

View Article and Find Full Text PDF

Staged Hybrid Management of a Mycotic Ascending Aortic Pseudoaneurysm.

Ann Thorac Surg Short Rep

December 2024

Division of Pediatric and Adult Congenital Cardiothoracic Surgery, Geisinger Medical Center, Danville, Pennsylvania.

Ascending aortic pseudoaneurysm may pose significant risk for reoperative repair. We describe an 18-year-old man who presented with bacteremia and a large, mycotic ascending aortic pseudoaneurysm 3 months after redo cardiac surgery. A covered stent graft sealed the pseudoaneurysm neck and facilitated safe reentry into the mediastinum.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!