Comparing two-zone models of dust exposure.

J Occup Environ Hyg

ENVIRON International Corporation, Chicago, Illinois 60606, USA.

Published: September 2011

The selection and application of mathematical models to work tasks is challenging. Previously, we developed and evaluated a semi-empirical two-zone model that predicts time-weighted average (TWA) concentrations (Ctwa) of dust emitted during the sanding of drywall joint compound. Here, we fit the emission rate and random air speed variables of a mechanistic two-zone model to testing event data and apply and evaluate the model using data from two field studies. We found that the fitted random air speed values and emission rate were sensitive to (i) the size of the near-field and (ii) the objective function used for fitting, but this did not substantially impact predicted dust Ctwa. The mechanistic model predictions were lower than the semi-empirical model predictions and measured respirable dust Ctwa at Site A but were within an acceptable range. At Site B, a 10.5 m3 room, the mechanistic model did not capture the observed difference between PBZ and area Ctwa. The model predicted uniform mixing and predicted dust Ctwa up to an order of magnitude greater than was measured. We suggest that applications of the mechanistic model be limited to contexts where the near-field volume is very small relative to the far-field volume.

Download full-text PDF

Source
http://dx.doi.org/10.1080/15459624.2011.598762DOI Listing

Publication Analysis

Top Keywords

dust ctwa
12
mechanistic model
12
model
8
two-zone model
8
emission rate
8
random air
8
air speed
8
predicted dust
8
model predictions
8
dust
5

Similar Publications

[Investigation of serum surface active protein D and clara cell protein levels in workers exposed to silica dust in ferrous metal foundry].

Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi

September 2023

Zhejiang Provincial Key Laboratory of Health Risk Appraisal for Trace Toxic Chemicals, Department of Environmental and Occupational Health, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China.

To investigate the levels of serum surface active protein D (SP-D) and clara cell protein (CCl6) in workers exposed to black silica dust, and analyze its influencing factors. From July to September 2021, 174 workers in 37 positions exposed to silica dust in 5 ferrous metal foundry were investigated by cross-sectional research method. The exposure concentration of silica dust workers was obtained through occupational health field investigation and detection, and the general situation of the study subjects was obtained through questionnaire survey and peripheral blood was collected.

View Article and Find Full Text PDF

To investigate the occupational hazard factors of different industries in Tongliao City, and to provide scientific basis for the prevention and control of occupational disease in Tongliao City. In July 2021, the detection data of coal dust, silica dust, cement dust, benzene, noise and other occupational hazard factors, as well as the occupational health examination data of workers in various positions of 104 enterprises in different industries in Tongliao City were cllected and anylazed. χ(2) test was used to analyze the results of chest radiography of workers in different age groups.

View Article and Find Full Text PDF

To investigate the occupational hazard factors and exposure levels of workers during the construction of power transmission and transformation projects. Analysis and identification of occupational hazard factors were carried out for typical construction process of 6 power transmission projects and 3 substation projects in September 2018. The on-site occupational health investigation was carried out to detect and analyze the exposure levels of workers to occupational hazard factors.

View Article and Find Full Text PDF
Article Synopsis
  • A study was conducted to assess the effectiveness of a cabinet-type water curtain exhaust hood in controlling silicon dust emissions from small sandblasting machines, aimed at improving worker health.
  • The research involved occupational health surveys, air distribution simulations, and smoke emission tests to evaluate silica dust concentration and control measures before and after implementing the exhaust hood.
  • Results showed that the installation significantly improved dust capture efficiency, reducing total dust concentrations from 7.00 mg/m(3) to 0.50 mg/m(3) and respirable dust from 3.36 mg/m(3) to 0.27 mg/m(3), demonstrating a 92% reduction in dust levels, making it a viable solution for similar industries.
View Article and Find Full Text PDF

To investigate occupational hazards in waste incineration power generation enterprises. From May 2016 to September 2018, four garbage incineration power generation enterprises in different regions and scales were selected as the survey objects. Investigated and analyzed the types of occupational hazards, workplace distribution and occupational disease prevention facilities and the concentration (intensity) of major types of work and workplace occupational hazards were also improved Line detection and analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!