Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The pharmacokinetics of ophthalmic biotherapeutics are difficult to determine in human vitreous humor. Because of the high transparency of living tissue to near-infrared (NIR) light, the temporal changes in vitreous concentrations of a biomolecule labeled with an NIR fluorescent probe can be monitored in situ with a scanning laser ophthalmoscope (SLO).
Methods: A humanized IgG was labeled with the NIR probe IRDye800CW (CVX-4164). Rabbits were given CVX-4164 intravitreally, and NIR fluorescence intensity was measured in the central plane of the vitreous humor with an SLO. Fluorescence intensities were converted to concentrations by using standard curves.
Results: Little background fluorescence was detected, and the minimum detectable concentration of CVX-4164 was <10 nM. Vitreal concentrations of CVX-4164 determined in situ declined with time, with C(max) ≈ 1 μM and t½ = 145 hours (112-μg dose). The t½ of CVX-4164 was approximately three times greater than that of the IRDye800CW alone, whereas the vitreal clearance (CL) and volume of distribution (V(ss)) of the native dye were approximately 2000- and 550-fold greater than that of the conjugate. CVX-4164 concentrations determined in situ were 2.6 to 4.4 times higher than those determined by ex vivo NIR fluorescence or ELISA in homogenized vitreous humor, reflecting the greater spatial resolution of in situ imaging. Moreover, vitreal concentrations determined in situ were >3 orders of magnitude greater than plasma concentrations of CVX-4164, as determined by ELISA, and had a different kinetic profile.
Conclusions: This study demonstrates the feasibility of determining the pharmacokinetics of intraocular biotherapeutics labeled with NIR fluorescent probes by in situ monitoring.