Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety.

Br J Radiol

Department of Radiology, School of Medicine, Ewha Womans University, Seoul, Republic of Korea.

Published: June 2012

Objective: The purpose of this study was to evaluate the diagnostic accuracy and safety of performing transthoracic needle biopsy (TNB) under combined fluoroscopy and CT guidance using a C-arm cone-beam CT (CBCT) system.

Methods: We evaluated the diagnostic accuracy and safety of performing TNB using a C-arm CBCT system. We retrospectively evaluated 99 TNB cases performed in 98 patients using a C-arm CBCT system with an 18-gauge automated cutting needle. We reviewed the diagnostic accuracy according to the size and depth of the lesion, incidence of complications, additional treatment for complications, procedure time, number of needle passes per biopsy and radiation dose.

Results: The final diagnoses revealed 72 malignant and 27 benign lesions. The overall malignancy sensitivity, malignancy specificity and diagnostic accuracy were 95.8%, 100% and 97.0%, respectively, and those for small pulmonary nodules <20 mm in size were 94.1%, 100% and 96.6%, respectively. There was no significant difference in the correct diagnosis of malignancy according to lesion size (p = 0.634) or depth (p = 0.542). For benign lesions, a specific diagnosis was obtained in 14 cases (51.9%). TNB induced complications in 19 out of 99 procedures (19.2%), including pneumothorax (16.2%), immediate haemoptysis (2.0%) and subcutaneous emphysema (1.0%). Among these, four patients with pneumothorax required chest tube insertion (2.0%) or pig-tail catheter drainage (2.0%). The mean procedure time, number of needle passes and radiation doses were 11.9 ± 4.0 min, 1.2 ± 0.5 times and 170.0 ± 67.2 mGy, respectively.

Conclusion: TNB using a C-arm CBCT system provides high diagnostic accuracy with a low complication rate and a short procedure time, particularly for small pulmonary nodules.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3474102PMC
http://dx.doi.org/10.1259/bjr/95413532DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
20
accuracy safety
12
transthoracic needle
8
needle biopsy
8
c-arm cone-beam
8
safety performing
8
c-arm cbct
8
cbct system
8
diagnostic
5
accuracy
5

Similar Publications

Postural stability measures as diagnostic tools for chronic ankle instability: a comprehensive assessment.

BMC Sports Sci Med Rehabil

January 2025

Department of Physiotherapy, School of Rehabilitation, Tehran University of Medical Science, Enghelab St, Pich-e-Shemiran, Tehran, Iran.

Background: Chronic ankle instability (CAI) is characterized by recurrent sprains and persistent symptoms, which impair postural control. This study evaluates the diagnostic utility of various linear and nonlinear postural stability measures in distinguishing individuals with CAI from healthy controls.

Methods: Postural stability was assessed in 24 participants (12 with CAI and 12 healthy controls) using a force platform under four conditions: hard surface with eyes open, hard surface with eyes closed, soft surface with eyes open, and soft surface with eyes closed.

View Article and Find Full Text PDF

Background: Optical spectral transmission (OST) is a modern diagnostic method capable of quantifying inflammation in the finger and wrist joints of arthritis patients by assessing the blood-specific absorption of light transmitted through a tissue. The diagnostic performance of this modality has not been adequately examined and data regarding OST associations with magnetic resonance imaging (MRI) are limited. Aim of this study was therefore to investigate the performance of OST in assessing joint inflammation as compared to MRI in patients with inflammatory arthritis (IA).

View Article and Find Full Text PDF

Background: Intrahepatic cholestasis of pregnancy (ICP) is a liver disorder that occurs in the second and third trimesters of pregnancy and is associated with a significant risk of fetal complications, including premature birth and fetal death. In clinical practice, the diagnosis of ICP is predominantly based on the presence of pruritus in pregnant women and elevated serum total bile acid. However, this approach may result in missed or delayed diagnoses.

View Article and Find Full Text PDF

Purpose: To evaluate the staging performance of positron emission tomography/magnetic resonance imaging (PET/MRI) for confirmed esophageal cancer based on the TNM classification system as well as compare it to other alternative modalities (e.g., endoscopic ultrasonography (EUS), computed tomography (CT), MRI, and PET/CT) in a full head-to-head manner.

View Article and Find Full Text PDF

Background: The burden of Clostridioides difficile as a nosocomial- and community-acquired pathogen has been increasing over the recent decades, including reports of severe outbreaks. Molecular and virulence genotyping are central for the epidemiological surveillance of this pathogen, but need to balance accuracy and rapid turnaround time of the results. While Illumina short-read sequencing has been adopted as the gold standard to investigate C.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!