A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of anterior transgastric access techniques for natural orifice translumenal endoscopic surgery. | LitMetric

Background: The advancement of natural orifice translumenal endoscopic surgery (NOTES) into clinical practice is dependent on its safety, efficacy, and efficiency. Access is the obligatory first step in NOTES and serves as a surrogate to technical difficulties associated with this novel surgical approach. This study aimed to compare endoscopic transgastric access techniques in terms of safety, reproducibility, and efficiency.

Methods: Seven variations for anterior transgastric NOTES access were evaluated with female domestic swine. After marking of an anterior site, electrocautery was used to create a small gastrotomy, followed by balloon dilation and entry into the peritoneal cavity. Methodologic variations incorporated the use of guidewires, electrocautery and dilation combined within a single device, support tubes, and dilation without electrocautery. Access times were recorded, and tissue injury was evaluated.

Results: In 70 access attempts, the most serious complication was bleeding from the gastroepiploic vessel, controlled with electrocautery. High variability in access times was prevalent with almost all the access techniques.

Conclusions: This study supports the presumption that an anterior transgastric access technique for NOTES procedures is safe. The use of a wire to mark the site and another wire to retain the gastrotomy provided safe, efficient, and reproducible transgastric access. Comparison with laparoscopy exposed the disparity in technical challenges facing NOTES, suggesting that new technology and further refinement in methodology are required for NOTES to be clinically relevant.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-011-1818-7DOI Listing

Publication Analysis

Top Keywords

transgastric access
16
anterior transgastric
12
access
10
access techniques
8
natural orifice
8
orifice translumenal
8
translumenal endoscopic
8
endoscopic surgery
8
access times
8
notes
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!