A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Anterior-posterior asymmetry in iris mechanics measured by indentation. | LitMetric

Anterior-posterior asymmetry in iris mechanics measured by indentation.

Exp Eye Res

Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN 55455, USA.

Published: October 2011

Indentation and histological analysis of the porcine iris were done to assess the relative stiffness of the anterior (stroma) and posterior (dilator and sphincter) layers. The dimensions of the constituent structures were documented histologically by staining with a monoclonal anti-human α-smooth muscle actin antibody to determine the location of the stroma, sphincter, and dilator. Intact porcine irides (4-8 h post-mortem) were bisected into two equal C-shaped halves to indent both surfaces. Indentation experiments were performed using a 1 mm cylindrical indenter tip. The load-displacement curve for each experiment was used to estimate effective instantaneous and equilibrium moduli for the anterior and posterior surfaces of the tissue. A total of 18 irides (9 pairs) with 3-5 indentations per iris surface was performed. The average thickness of the samples was 550 μm; the indentation depth was limited to 60-100 μm depending on the thickness of the sample at each point. Posterior surface indentation gave larger forces than anterior, with the resulting instantaneous modulus of 6.0 ± 0.6 kPa versus 4.0 ± 0.5 kPa (mean ± 95% CI, n = 45, p < 0.001) and equilibrium modulus of 4.4 ± 0.9 versus 2.3 ± 0.3 (p = 0.007). The stress-relaxation analysis revealed that the anterior surface had a shorter relaxation time (121.31 ± 6.84 s) than the posterior surface (210.61 ± 9.41 s, p = 0.03), perhaps due to the permeability of the stroma. Recognizing that our effective modulus calculations in this study did not account for heterogeneity, viscoelasticity, or poroelasticity, we conclude that the posterior components of the iris - dilator, pigment epithelium, and sphincter - are on average stiffer than the stroma and anterior border layer.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.exer.2011.06.009DOI Listing

Publication Analysis

Top Keywords

indentation
5
anterior-posterior asymmetry
4
asymmetry iris
4
iris mechanics
4
mechanics measured
4
measured indentation
4
indentation indentation
4
indentation histological
4
histological analysis
4
analysis porcine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!