Distributed source x-ray tube technology for tomosynthesis imaging.

Proc SPIE Int Soc Opt Eng

XinRay Systems LLC, Research Triangle Park, NC, USA.

Published: January 2010

Tomosynthesis imaging requires projection images from different viewing angles. Conventional systems use a moving xray source to acquire the individual projections. Using a stationary distributed x-ray source with a number of sources that equals the number of required projections, this can be achieved without any mechanical motion. Advantages are a potentially faster image acquisition speed, higher spatial and temporal resolution and simple system design. We present distributed x-ray sources based on carbon nanotube (CNT) field emission cathodes. The field emission cathodes deliver the electrons required for x-ray production. CNT emitters feature a stable emission at high current density, a cold emission, excellent temporal control of the emitted electrons and good configurability. We discuss the use of stationary sources for two applications: (i) a linear tube for stationary digital breast tomosynthesis (sDBT), and (ii) a square tube for on-board tomosynthesis image-guided radiation therapy (IGRT). Results from high energy distributed sources up to 160kVp are also presented.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3139949PMC
http://dx.doi.org/10.1117/12.844586DOI Listing

Publication Analysis

Top Keywords

tomosynthesis imaging
8
distributed x-ray
8
field emission
8
emission cathodes
8
distributed
4
distributed source
4
x-ray
4
source x-ray
4
x-ray tube
4
tube technology
4

Similar Publications

Breast MRI to Screen Women With Extremely Dense Breasts.

J Magn Reson Imaging

January 2025

Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.

Women with extremely dense breasts are at a higher risk of breast cancer, and the sensitivity of mammography in this group is reduced due to the masking effect of overlapping tissue. This review examines supplemental screening methods to improve detection in this population, with a focus on MRI. Morphologic techniques offer limited benefits, digital breast tomosynthesis (DBT) shows inconsistent results, and ultrasound (US), while improving cancer detection rates (CDR), results in a higher rate of false positives.

View Article and Find Full Text PDF

Purpose: Digital Breast Tomosynthesis (DBT) is an advanced mammography technique for which there are currently no internationally agreed methods and reference values for image quality assessment. The aim of this multicentre study was to evaluate a simple method to assess the technical image quality of reconstructed and synthetic 2D (SM) images of different models of DBT systems using commercially available phantoms.

Methods: The signal difference to noise ratio (SDNR) was chosen as an index of technical image quality and was evaluated for three commercial phantoms, Tomophan, Tormam and CIRS model 015, on 55 DBT systems (six vendors, nine models).

View Article and Find Full Text PDF

Background: The American Association of Physicists in Medicine (AAPM) Task group 282 (TG282) in collaboration with the European Federation for Organisations of Medical Physics (EFOMP) have developed a novel breast dosimetry model intended as a single international standard.

Purpose: To explore the impact of TG282 dosimetry on estimates of average Mean Glandular Dose (MGD) in the United Kingdom (UK) National Health Service (NHS) Breast Screening Programmes (BSP).

Methods: MGDs were estimated, using the TG282 dosimetry model, for the most recent UK NHSBSP dose survey.

View Article and Find Full Text PDF

Comparing synthetic mammograms based on wide-angle digital breast tomosynthesis with digital mammograms.

J Med Imaging (Bellingham)

January 2025

Lund University, Department of Translational Medicine, Medical Radiation Physics, Malmö, Sweden.

Purpose: We aim to investigate the characteristics and evaluate the performance of synthetic mammograms (SMs) based on wide-angle digital breast tomosynthesis (DBT) compared with digital mammography (DM).

Approach: Fifty cases with both synthetic and digital mammograms were selected from the Malmö Breast Tomosynthesis Screening Trial. They were categorized into five groups consisting of normal cases and recalled cases with false-positive and true-positive findings from DM and DBT only.

View Article and Find Full Text PDF

Vertebral fractures are a common and debilitating consequence of osteoporosis. Bone mineral density (BMD), measured by dual energy x-ray absorptiometry (DXA), is the clinical standard for assessing overall bone quantity but falls short in accurately predicting vertebral fracture. Fracture risk prediction may be improved by incorporating metrics of microstructural organization from an appropriate imaging modality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!