Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The aim of the present study was to evaluate the interplay between microstructure and function of the bone around an immediately loaded implant retrieved from human maxilla after 23 months due to fracture. A spiral implant of 3.3 mm x 15 mm was placed in a male 53 years old in the anterior region of the mandible bone (4.1) and it was processed for histology. The specimen was analyzed under the confocal scanning laser microscope (CSLM) and brightfield light microscope (LM) equipped with circularly polarized light (CPL). The BIC rate was 76.7 ± 4.9 (mean ±SD). Many cement lines indicates an high remodeling rate of the bone. The transverse collagen fiber orientation (CFO) (mean±SD) under the lower flank of the thread near the tread tip was 55.2 ± 4.8 x 10(4) pixel while the longitudinal CFO was 45.8 ± 2.3 x 10(4) pixel (P<.05). In the inter-threads region the transverse CFO (mean ±SD) was 36.4 ± 2.4 x 10(4) pixel while the longitudinal CFO was 65.6 ± 6.5 x 10(4) pixel (P<.05). The osteocytes numbers (mean ±SD) was 205 ± 45 in the peri-implant bone and 144 ± 53 in the native bone (P=.007). After 2-years of loading the SLA spiral implant was well osseointegrated but still surrounded by woven bone. The osteocytes density was significantly higher in the peri-implant bone than in the native bone. The transverse collagen fibers were significantly associated with the lower flank of the implant threads, while the longitudinal collagen fibers were more represented in the straight surface of the implant. The implant fracture was correlated to crestal bone resorbing and subsequent fatigue yielding.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/03946320110240S207 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!