A novel liver retraction technique for lateral lobe of the liver during laparoscopic surgery using silicone disk.

J Laparoendosc Adv Surg Tech A

Department of Upper Gastrointestinal Surgery, Hyogo College of Medicine, Nishinomiya City, Hyogo, Japan.

Published: October 2011

AI Article Synopsis

  • The study presents a new laparoscopic liver retraction technique using a silicone disk that eliminates the need for additional incisions and minimizes the risk of liver injury during various surgeries.
  • The device consists of a flexible ring with a silicone membrane and monofilament threads, allowing safe retraction of the liver while maintaining an optimal view of the surgical area.
  • This innovative approach has been used in multiple laparoscopic procedures without any complications, significantly reducing liver damage and enhancing surgical outcomes.

Article Abstract

For safe and effective laparoscopic surgery it is important to maintain a favorable view of the operative field. However, the use of a conventional liver retractor needs an additional wound and carries a risk for liver injury during surgery. We developed a novel retraction technique for the lateral lobe of the liver using a silicone disk (Hakko Co. Ltd.) during laparoscopic surgery. We used a silicone disk that consists of a silicone rubber membrane inside a flexible ring and four monofilament threads. The disk can be inserted into the abdomen under the pneumoperitoneum through a 12-mm port and is located at the dorsal side of the lateral lobe of the liver. The threads are withdrawn through the abdominal wall, two threads close to the infraxiphoid space and the other two threads bilaterally below the costal arch. Thus, the lateral lobe of the liver is safely raised to the ventral side and covered with a silicone membrane. We introduced this technique for various laparoscopic operations, such as gastrectomy, gastroplasty, and fundoplication. There were no complications related to the procedure. This retraction technique is easy, results in less liver damage, and provides an excellent operative view around the esophageal hiatus. The silicone membrane covering the lateral lobe reduces the risk of liver injury during surgery using laparoscopic forceps to a low level.

Download full-text PDF

Source
http://dx.doi.org/10.1089/lap.2011.0161DOI Listing

Publication Analysis

Top Keywords

lateral lobe
20
lobe liver
16
retraction technique
12
laparoscopic surgery
12
silicone disk
12
technique lateral
8
liver
8
surgery silicone
8
risk liver
8
liver injury
8

Similar Publications

Aim: The tubercle of Zuckerkandl (TZ) is considered to be the fusion point of the ultimabranchial body and the median thyroid body. We aimed to evaluate the frequency of TZ and its relationship with other anatomical variations and recurrent laryngeal nerve (RLN) paralysis.

Material And Methods: Data regarding the thyroid lobe and RLN of patients with thyroidectomy between June 2016 and December 2019 were retrospectively evaluated.

View Article and Find Full Text PDF

Background And Purpose: The magnetic resonance images (MRIs) ability of lesion detection in epilepsy is crucial for a diagnosis and surgical outcome. Using automated artificial intelligence (AI)-based tools for measuring cortical thickness and brain volume originally developed for dementia, we aimed to identify whether it could lateralize epilepsy with normal MRIs.

Methods: Non-lesional 3-Tesla MRIs of 428 patients diagnosed with focal epilepsy, based on semiology and electroencephalography findings, were analyzed.

View Article and Find Full Text PDF

From Prone to Prepared: Airway Management in a Patient With Penetrating Thoracic Trauma.

Cureus

December 2024

Anesthesiology, Unidade Local de Saúde de São José, Lisbon, PRT.

Perioperative and critical care management following penetrating thoracic trauma represents a complex challenge. Those who survive the early trauma approach and reach the hospital alive often remain in critical condition, with cardiocirculatory complications and major pulmonary injuries. Additional difficulty arises from the presence of a weapon , particularly in a dorsal location, which limits patient positioning, and the safe manipulation of both the weapon and the patient.

View Article and Find Full Text PDF

The final instar larva of the rare species Hämäläinen, 2003 is described and illustrated here for the first time, including a new distribution record from Vietnam. The larva of differs from that of congeneric species by distinct morphological features, including the presence of four setae on the palpal lobe of the labium, the presence of lateral spines on abdominal S5-9, and a long terminal filament on the caudal lamella. We also provide a key to species for the known larvae of the subfamily Platycnemidinae in the Sino-Japanese and Oriental regions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!