Purpose Of The Study: The purpose was to study the biomechanics of bone fracture repair, of the orbital floor, using osteosynthetic bioresorbable implant and how to improve the implant design.
Materials And Methods: A finite element model of the orbit and the globe of 1 patient who experienced orbital blowout fracture and treated with bioresorbable poly-L/DL-lactide (P[L/DL]LA 70:30) implant (PolyMax; Synthes, Oberdorf, Switzerland) was generated based on computed tomographic scans. Simulations were performed with a computer using a commercially available finite element software. The effects of changing the geometry, bony support, and method of fixation of the implant on the finite element model predictions were investigated.
Results: The factor that had the biggest impact on the predicted principal strain magnitudes was absence of bony support of the implant (up to 65%). Applying elastic fixation reduced stresses (up to 40%) posteriorly. The principal stresses inside the bone and the implant were evenly distributed when elastic fixation was applied to the implant. Applying rigid fixation increased stresses (up to 50% and 80% anteriorly and posteriorly, respectively). The resulting stress values indicated a likely rapid failure of the osteosynthetic implant when rigid fixation was applied.
Conclusions: Applying rigid fixation induced a significant increase in stress patterns. Principal stresses were reduced remarkably when elastic fixation was applied to the implant. The role of fixation becomes more prominent when there is no bony support posteriorly and/or medially. It is recommended to avoid rigid fixation and to apply elastic fixation when using bioresorbable P(L/DL)LA 70:30 implants to reconstruct inferior orbital wall bony defects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/SCS.0b013e31821c6ae9 | DOI Listing |
J Orthop
August 2025
University of Alabama at Birmingham, Department of Orthopaedic Surgery, Birmingham, AL, USA.
Purpose: This study aims to compare the biomechanical performance of elastic and static suture-based cerclage systems to traditional screw constructs in the setting of modeled glenoid bony augmentation.
Methods: Biomechanical testing was conducted on polyurethane cellular foam blocks modeling a 20 % glenoid defect repaired with a coracoid graft. Constructs consisted of an elastic suture-based cerclage, static suture-based cerclage, and a two-screw construct.
Front Bioeng Biotechnol
January 2025
Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China.
Background: Currently, some novel rods with lower elastic modulus have the potential as alternatives to traditional titanium alloy rods in lumbar fusion. However, how the elastic modulus of the rod (rod-E) influences the biomechanical performance of lumbar interbody fusion remains unclear. This study aimed to explore the quantitative relationships between rod-E and the biomechanical performance of transforaminal lumbar interbody fusion (TLIF).
View Article and Find Full Text PDFCarbohydr Polym
March 2025
School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea; Department of Health Sciences and Technology, Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea; Department of MetaBioHealth, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea; Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea; Institute of Quantum Biophysics (IQB), Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea. Electronic address:
Tendons are anisotropic tissues with exceptional mechanical properties, which result from their unique anisotropic structure and mechanical behavior under stress. While research has focused on replicating anisotropic structures and mechanical properties of tendons, fewer studies have examined their specific mechanical behaviors. Here, we present a simple method for creating calcium-crosslinked alginate-based double-network hydrogels that mimics tendons by exhibiting anisotropic structure, high mechanical strength and toughness, and a distinctive "toe region" when stretched.
View Article and Find Full Text PDFJ Orthop Sci
January 2025
Department of Orthopaedic Surgery, Wuhan Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. Electronic address:
Background: Length unstable femoral shaft fractures in school-aged children usually demand surgical treatment, but the optimal choice remains controversial, especially in overweight adolescents. This study aimed to compare the clinical results of locking compression plates (LCP) and elastic stable intramedullary nails (ESIN) combined with temporary external fixator (TEF) in school-aged children weighing over 50 kg.
Methods: Between January 2010 and January 2018, children over 50 kg with length unstable femoral shaft fracture treated with ESIN & EF in the authors' institute were included in this study.
J Clin Med
January 2025
Discipline of Physiotherapy, Faculty of Health Sciences, European University Miguel de Cervantes, C del Padre Julio Chevalier 2, 47012 Valladolid, Spain.
: Hip fractures are prevalent among the elderly and impose a significant burden on healthcare systems due to the associated high morbidity and costs. The increasing use of intramedullary nails for hip fracture fixation has inadvertently introduced risks; these implants can alter bone elasticity and create stress concentrations, leading to peri-implant fractures. The aim of this study is to investigate the outcomes of peri-implant hip fractures, evaluate the potential causes of such fractures, determine the type of treatment provided, assess the outcomes of said treatments, and establish possible improvement strategies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!