A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High kilovoltage digital exposure techniques and patient dosimetry. | LitMetric

High kilovoltage digital exposure techniques and patient dosimetry.

Radiol Technol

Department of Radiation Sciences, School of Allied Health Professions, at the Virginia Commonwealth University in Richmond, USA.

Published: December 2011

Purpose: To explore digital exposure techniques during pelvic imaging on patient dosimetry, exposure indicator (EXI) values and image quality.

Methods: An experimental design was used to study the effect of varying kilovoltage peak (kVp) and milliampere-seconds (mAs) on a male phantom pelvis when using a direct digital radiography (DR) flat panel detector. The radiation intensity was varied by increasing the kVp and reducing mAs. Image quality was evaluated by assessing density, density differences, quantum noise and overall diagnostic quality.

Results: When the kVp was increased in 15% increments and mAs divided by half, the radiation dose to the gonads significantly decreased. The lowest and highest kVp exposure groups produced the lowest EXI values. There was no correlation between the thermoluminescent dosimeter milliroentgen (mR) measurements and the EXI values.

Conclusion: The results indicate that a pelvic DR image produced at 93 kVp and 12.5 mAs will reduce the gonadal dose while maintaining an image of diagnostic quality.

Download full-text PDF

Source

Publication Analysis

Top Keywords

digital exposure
8
exposure techniques
8
patient dosimetry
8
exi values
8
kvp
5
high kilovoltage
4
kilovoltage digital
4
exposure
4
techniques patient
4
dosimetry purpose
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!