Aims: Cardiac resynchronization therapy (CRT) is an effective treatment for a subset of patients with chronic heart failure. Data on the benefit of CRT in heart failure patients with previous right ventricular pacemakers or standard defibrillators are sparse.

Methods And Results: The European (HFA, Heart Failure Association/EHRA, European Heart Rhythm Association) CRT Survey enrolled patients from 141 centres in 13 countries in Europe collecting baseline demographic, echocardiographic, clinical, and implant data, with follow-up at ∼1 year. The present analysis reports implantation data and 1 year outcomes regarding New York Heart Association (NYHA) class, global patient assessment, hospitalizations, complications, and mortality in patients undergoing de novo CRT implantations compared with those receiving an upgrade of a previously implanted device (pacemaker or implantable cardioverter-defibrillators). This analysis includes 2367 CRT implant procedures of which 692 (28%) were upgrades to CRT. Distribution of NYHA functional class and left ventricular function were similar between the groups. Procedural duration was also similar, although fluoroscopy time was shorter in the 'upgrades'. There was no difference in the frequency of peri-procedural complications. There were similar improvements in NYHA functional class and similar reduction in QRS duration, but more patients reported unchanged global assessment status in the upgraded group. Total and cause-specific mortality at 1 year was low and the same in both groups.

Conclusions: More than one quarter of all CRT procedures are upgrades from existing systems, although this group has not been subject to randomized clinical trials. Our data suggest that there are no significant differences in clinical outcomes or complication rates between upgrades and de novo procedures. Clinical study no NCT 01185392.

Download full-text PDF

Source
http://dx.doi.org/10.1093/eurjhf/hfr085DOI Listing

Publication Analysis

Top Keywords

cardiac resynchronization
12
resynchronization therapy
12
heart failure
12
nyha functional
8
functional class
8
crt
7
patients
5
heart
5
european cardiac
4
therapy survey
4

Similar Publications

Left bundle branch area pacing (LBBAP) can effectively enhance cardiac contraction by engaging the conduction system. LBBAP, compared with right ventricular apex pacing, can reduce QRS duration and enhance left ventricular function. Consequently, LBBAP has been proposed as a viable alternative to cardiac resynchronization therapy (CRT).

View Article and Find Full Text PDF

Cardiac implantable electronic devices (CIEDs), including pacemakers, implantable cardiac defibrillators (ICD), and cardiac resynchronization therapy (CRT) devices, regulate heart rate and rhythm in patients with cardiac conditions. With an aging population, CIED-related complications, especially pacemaker pocket infections, are rising. Risk factors include frailty, older age, and superficial device fixation, while risk mitigation involves larger pocket sizes, submuscular fixation, and absorbable antibacterial envelopes.

View Article and Find Full Text PDF

This paper reviews the literature on assessing electrical dyssynchrony for patient selection in cardiac resynchronization therapy (CRT). The guideline-recommended electrocardiographic (ECG) criteria for CRT are QRS duration and morphology, established through inclusion criteria in large CRT trials. However, both QRS duration and LBBB morphology have their shortcomings.

View Article and Find Full Text PDF

: Heart failure is the leading cause of hospital admission and mortality. Racial disparities have been demonstrated in various cardiovascular disorders; however, the data for in-hospital outcomes, complications, and procedural rates are limited. : Utilizing the National Inpatient Sample (NIS) database, this retrospective cohort study included adult patients admitted with a principal diagnosis of heart failure.

View Article and Find Full Text PDF

Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!