Electronic measures of surgical site infection: implications for estimating risks and costs.

Infect Control Hosp Epidemiol

Division of Outcomes Research and Quality, Department of Surgery, Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania 17033, USA.

Published: August 2011

Objective: Electronic measures of surgical site infections (SSIs) are being used more frequently in place of labor-intensive measures. This study compares performance characteristics of 2 electronic measures of SSIs with a clinical measure and studies the implications of using electronic measures to estimate risk factors and costs of SSIs among surgery patients.

Methods: Data included 1,066 general and vascular surgery patients at a single academic center between 2007 and 2008. Clinical data were from the National Surgical Quality Improvement Program (NSQIP) database, which includes a nurse-derived measure of SSI. We compared the NSQIP SSI measure with 2 electronic measures of SSI: MedMined Nosocomial Infection Marker (NIM) and International Classification of Diseases, Ninth Revision (ICD-9) coding for SSIs. We compared infection rates for each measure, estimated sensitivity and specificity of electronic measures, compared effects of SSI measures on risk factors for mortality using logistic regression, and compared estimated costs of SSIs for measures using linear regression.

Results: SSIs were observed in 8.8% of patients according to the NSQIP definition, 2.6% of patients according to the NIM definition, and 5.8% according to the ICD-9 definition. Logistic regression for each SSI measure revealed large differences in estimated risk factors. NIM and ICD-9 measures overestimated the cost of SSIs by 134% and 33%, respectively.

Conclusions: Caution should be taken when relying on electronic measures for SSI surveillance and when estimating risk and costs attributable to SSIs. Electronic measures are convenient, but in this data set they did not correlate well with a clinical measure of infection.

Download full-text PDF

Source
http://dx.doi.org/10.1086/660870DOI Listing

Publication Analysis

Top Keywords

electronic measures
32
risk factors
12
measures
11
electronic
8
measures surgical
8
surgical site
8
ssis
8
clinical measure
8
costs ssis
8
ssi measure
8

Similar Publications

Visible light has been considered to have minimal impact on the skin. However, the increasing use of electronic devices has led to a significant increase in exposure to visible light, especially blue light. We measured the irradiance (mW/cm) and estimated dose (J/cm) of visible light and blue light emitted from various electronic devices including smartphones, tablets and computers.

View Article and Find Full Text PDF

Molecular junctions (MJs) are celebrated nanoelectronic devices for mimicking conventional electronic functions, including rectifiers, sensors, wires, switches, transistors, negative differential resistance, and memory, following an understanding of charge transport mechanisms. However, capacitive nanoscale molecular junctions are rarely seen. The present work describes electrochemically (E-Chem) grown covalently attached molecular thin films of 10, 14.

View Article and Find Full Text PDF

Sweet potato ( (L.) Lam.) is a tuber root crop with high economical potential and China is responsible for harvesting roughly 70% of the world production.

View Article and Find Full Text PDF

Partial directed coherence analysis of resting-state EEG signals for alcohol use disorder detection using machine learning.

Front Neurosci

January 2025

Center of Excellence in Intelligent Engineering Systems (CEIES), Department of Electrical and Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah, Saudi Arabia.

Introduction: Excessive alcohol consumption negatively impacts physical and psychiatric health, lifestyle, and societal interactions. Chronic alcohol abuse alters brain structure, leading to alcohol use disorder (AUD), a condition requiring early diagnosis for effective management. Current diagnostic methods, primarily reliant on subjective questionnaires, could benefit from objective measures.

View Article and Find Full Text PDF

Introduction: Fluid overload (FO), a state of pathologic positive cumulative fluid balance (CFB), is common in Pediatric Intensive Care Units (PICU) and associated with morbidity and mortality. Because different PICUs may have unique needs, barriers, and limitations to accurately report fluid balance (FB) and reduce FO, understanding the drivers of positive FB is needed. We hypothesize CFB >5% and >10% is common within initial days of PICU admission, but that reasons for high %CFB will vary across sites, as will barriers to accurate FB recording and opportunities to improve FB recording and management.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!