Hypothesis: Despite the overall acceptance of laparoscopic donor nephrectomy (LDNX), concern remains about the application of this technique in certain complex situations, such as right-sided nephrectomies and in donors with complex kidney anatomy and obese donors. This study was designed to determine if complication rates have remained stable as we have offered LDNX to all medically acceptable donors and to analyze the results of cases in each of the complex categories. We hypothesized that complication rates in the 3 complex categories would be equivalent to those among more straightforward cases.

Design: Retrospective medical record review.

Setting: Academic medical center.

Patients: A total of 1045 patients who underwent LDNX between November 3, 1999, and August 28, 2009.

Main Outcomes Measures: Operative times, lengths of hospital stay, overall complications, major complications, conversions to open surgery, blood transfusions, readmissions, and reoperations.

Results: The outcomes of the first 250 patients (when LDNX was selectively offered) were compared with the outcomes of the last 795 patients (when LDNX was offered to all medically acceptable donors). Overall operative times significantly improved (212 vs 176 minutes), overall complication rates did not change (6.4% vs 5.5%), and major complication rates significantly declined (4.0% vs 1.4%). Among the last 795 patients, 1 conversion to open surgery and 1 blood transfusion occurred. There were no deaths in the series. Moreover, no differences in overall or major complication rates were seen when cases involving 200 right-sided nephrectomies, 204 donors with complex kidney anatomy, and 148 obese donors were analyzed independently.

Conclusions: Low complication rates persist for LDNX, even when applied to more technically challenging cases. This procedure is offered to all medically acceptable donors, with an excellent safety profile, and should be considered the standard of care for kidney donation.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archsurg.2011.156DOI Listing

Publication Analysis

Top Keywords

complication rates
28
medically acceptable
12
acceptable donors
12
laparoscopic donor
8
donor nephrectomy
8
low complication
8
challenging cases
8
right-sided nephrectomies
8
donors complex
8
complex kidney
8

Similar Publications

Objective: Tumor consistency, or fibrosity, affects the ability to optimally resect meningiomas, especially with recent trends evolving toward minimally invasive approaches. The authors' team previously validated a practical 5-point scale for intraoperative grading of meningioma consistency. The impact of meningioma consistency on surgical management and outcomes, however, has yet to be explored.

View Article and Find Full Text PDF

Objective: Aneurysmal subarachnoid hemorrhage (SAH) is associated with high morbidity and mortality rates. In particular, functional outcomes of SAH caused by large or giant (≥ 10 mm) ruptured intracranial aneurysms are worsened by high procedure-related complication rates. However, studies describing the risk factors for poor functional outcomes specific to ruptured large/giant aneurysms are sparse.

View Article and Find Full Text PDF

Objective: The goal of this study was to compare the impact of using a lower thoracic (LT) versus upper lumbar (UL) level as the upper instrumented vertebra (UIV) on clinical and radiographic outcomes following minimally invasive surgery for adult spinal deformity.

Methods: A multicenter retrospective study design was used. Inclusion criteria were age ≥ 18 years, and one of the following: coronal Cobb angle > 20°, sagittal vertical axis > 50 mm, pelvic tilt > 20°, pelvic incidence-lumbar lordosis mismatch > 10°.

View Article and Find Full Text PDF

Objective: To compare the 3-year outcomes of the modified minimally invasive Ponto surgery (m-MIPS) to both the original MIPS (o-MIPS) and linear incision technique with soft tissue preservation (LIT-TP) for inserting bone-anchored hearing implants (BAHIs).

Study Design: Prospective study with three patient groups: m-MIPS, o-MIPS, and LIT-TP.

Setting: Tertiary referral center.

View Article and Find Full Text PDF

Background: Belatacept is approved for the prophylaxis of organ rejection in Epstein-Barr virus (EBV)-seropositive kidney transplant recipients and is associated with a risk of post-transplant lymphoproliferative disorder (PTLD).

Methods: Data from the Organ Procurement and Transplantation Network were used to examine patterns of belatacept use, describe patient characteristics, and estimate risk of PTLD in EBV-seropositive, kidney-only transplant recipients receiving belatacept- or calcineurin inhibitor (CNI)-based immunosuppression as part of US Food and Drug Administration-mandated safety monitoring.

Results: During the study period (June 15, 2011-June 14, 2016), 94.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!