In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real-time PCR analysis is conducted on samples before and after incubation. The method, referred to as rapid-viability (RV)-PCR, uses the change in cycle threshold after incubation to detect the presence of live organisms. In this article, we report a novel RV-PCR method for detection of live, virulent Bacillus anthracis, in which the incubation time was reduced from 14 h to 9 h, bringing the total turnaround time for results below 15 h. The method incorporates a magnetic bead-based DNA extraction and purification step prior to PCR analysis, as well as specific real-time PCR assays for the B. anthracis chromosome and pXO1 and pXO2 plasmids. A single laboratory verification of the optimized method applied to the detection of virulent B. anthracis in environmental samples was conducted and showed a detection level of 10 to 99 CFU/sample with both manual and automated RV-PCR methods in the presence of various challenges. Experiments exploring the relationship between the incubation time and the limit of detection suggest that the method could be further shortened by an additional 2 to 3 h for relatively clean samples.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3187157PMC
http://dx.doi.org/10.1128/AEM.00623-11DOI Listing

Publication Analysis

Top Keywords

method detection
8
detection live
8
live virulent
8
virulent bacillus
8
bacillus anthracis
8
anthracis environmental
8
environmental samples
8
turnaround time
8
real-time pcr
8
pcr analysis
8

Similar Publications

Deep Equilibrium Unfolding Learning for Noise Estimation and Removal in Optical Molecular Imaging.

Comput Med Imaging Graph

January 2025

CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:

In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.

View Article and Find Full Text PDF

[F]FDG PET/CT versus Dynamic Contrast-Enhanced CT for the diagnosis of solitary pulmonary Nodule: A Head-to-Head comparative Meta-Analysis.

Eur J Radiol

January 2025

Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:

Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.

Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.

View Article and Find Full Text PDF

Feasibility of detecting non-small cell lung cancer using exhaled breath condensate metabolomics.

J Breath Res

January 2025

School of Medicine and Pharmacy, Ocean University of China, 5 Yushan Rd, Qingdao, Shandong, 266003, CHINA.

Lung cancer is one of the most common malignancy in the world, and early detection of lung cancer remains a challenge. The exhaled breath condensate (EBC) from lung and trachea can be collected totally noninvasively. In this study, our aim is to identify differential metabolites between non-small cell lung cancer (NSCLC) and control EBC samples and discriminate NSCLC group from control group by orthogonal projections to latent structures-discriminant analysis (OPLS-DA) models.

View Article and Find Full Text PDF

Objectives: Home blood pressure monitoring (HBPM) is valuable for the detection and monitoring of hypertension. Despite logistical advantages, HBPM has not yet been used in national blood pressure (BP) surveys. We investigated randomly selected adults' willingness to participate in an HBPM study (attitude survey) and piloted this approach (feasibility study).

View Article and Find Full Text PDF

Background: Surgical site infection (SSI) is a significant complication following pediatric cardiovascular surgery. Although drain tip cultures (DTC) are sometimes used postoperatively to predict SSIs, their diagnostic value in pediatric cardiovascular surgery remains unclear. This study aimed to assess the diagnostic utility of DTC for predicting SSIs in pediatric cardiovascular surgery patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!