Purpose: To test the hypothesis that ruptured abdominal aortic aneurysms (AAA) are globally weaker than unruptured ones.
Methods: Four ruptured and seven unruptured AAA specimens were harvested whole from fresh cadavers during autopsies performed over an 18-month period. Multiple regionally distributed longitudinally oriented rectangular strips were cut from each AAA specimen for a total of 77 specimen strips. Strips were subjected to uniaxial extension until failure. Sections from approximately the strongest and weakest specimen strips were studied histologically and histochemically. From the load-extension data, failure tension, failure stress and failure strain were calculated. Rupture site characteristics such as location, arc length of rupture and orientation of rupture were also documented.
Results: The failure tension, a measure of the tissue mechanical caliber was remarkably similar between ruptured and unruptured AAA (group mean ± standard deviation of within-subject means: 11.2±2.3 versus 11.6±3.6N/cm; p=0.866 by mixed model ANOVA). In post-hoc analysis, there was little difference between the groups in other measures of tissue mechanical caliber as well such as failure stress (95±28 versus 98±23 N/cm(2); p=0.870), failure strain (0.39±0.09 versus 0.36±0.09; p=0.705), wall thickness (1.7±0.4 versus 1.5±0.4mm; p=0.470) , and % coverage of collagen within tissue cross section (49.6±12.9% versus 60.8±9.6%; p=0.133). In the four ruptured AAA, primary rupture sites were on the lateral quadrants (two on left; one on left-posterior; one on right). Remarkably, all rupture lines had a longitudinal orientation and ranged from 1 to 6 cm in length.
Conclusion: The findings are not consistent with the hypothesis that ruptured aortic aneurysms are globally weaker than unruptured ones.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2011.06.004 | DOI Listing |
J Neurointerv Surg
January 2025
Lyerly Neurosurgery, Baptist Medical Center Jacksonville, Jacksonville, Florida, USA
The Artisse intrasaccular device (Medtronic) offers a novel treatment option for unruptured and ruptured wide-neck bifurcating intracranial aneurysms.1 2The Artisse device features enhancements including a distal tip for dome protection, platinum band markers for improved visibility, and a bilayer high-density platinum core nitinol mesh basket for enhanced flexibility and visibility when compared with previous devices.2-7 Data from case series demonstrate the procedural safety and efficacy of the Artisse device.
View Article and Find Full Text PDFWorld Neurosurg
December 2024
Department of Neurosurgery, Interdisciplinary Graduate School of Medicine and Engineering, University of Yamanashi, Chuo, Japan.
Background: Flow diverters (FDs) have been introduced for the management of large or giant cavernous carotid aneurysms (CCAs) in addition to conventional modalities, dramatically changing treatment strategies. The aim of this study was to examine the management of unruptured large/giant CCAs in Japan when FDs were being introduced using a nationwide survey.
Methods: 540 unruptured large/giant CCAs treated at neurosurgical teaching departments in Japan between 2012 and 2016 were retrospectively studied.
Int J Surg Case Rep
December 2024
University of Gondar College of Medicine and Health Sciences, Ethiopia.
Introduction: Mucinous appendiceal neoplasms are unique tumors in which >50 % of the tumor volume is composed of extracellular mucin. They may present as an unruptured mucin-filled appendix or, more commonly, with peritoneal metastases after rupture or transmural invasion of the primary tumor. This case report describes a case of presumed ovarian malignancy with final pathologic diagnosis of low grade appendiceal mucinous neoplasm.
View Article and Find Full Text PDFFront Neurol
December 2024
Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Ann Vasc Dis
December 2024
This is an annual report indicating the number and early clinical results of annual vascular treatment performed by vascular surgeons in Japan in 2017, as analyzed by Database Management Committee (DBC) members of the Japanese Society for Vascular Surgery (JSVS). To survey the current status of vascular treatments performed by vascular surgeons in Japan, the DBC members of the JSVS analyzed the vascular treatment data provided by the National Clinical Database, including the number of treatments and early results such as operative and hospital mortality. In total, 137,909 vascular treatments were registered by 1,076 institutions in 2017.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!