Objective: To develop a HPLC method for the determination of evodiamine and rutacarpine in Zhuyu Hewei Zhitong capsules.

Method: The separation was performed at 30 degrees C on an Eclipse XDB-C18 column (4.6 mm x 150 mm, 5 microm) eluted with the mobile phase consisted of acetonitrile-water(45:55). The detection wavelength was 250 nm.

Results: The standard curve for evodiamine is linear in the range of 0.0510-0.560 microg, the average recovery was 97.5% (RSD 1.0%). The standard curve for rutacarpine is linear in the range of 0.0508-0.559 microg, the average recovery was 98.7% (RSD 1.5%).

Conclusion: The method is specific, accurate and stable. It can be used for detemination of evodiamine and rutacarpine in Zhuyu Hewei Zhitong capsules.

Download full-text PDF

Source

Publication Analysis

Top Keywords

evodiamine rutacarpine
12
rutacarpine zhuyu
12
zhuyu hewei
12
hewei zhitong
12
zhitong capsules
8
standard curve
8
linear range
8
microg average
8
average recovery
8
[determination evodiamine
4

Similar Publications

A simple and sensitive method for simultaneous determination of seven active constituents, jatrorrhizine, berberine, coptisine, palmatine, evodiamine, rutacarpine and paeoniflorin, from a Chinese medicine Wuji Pill in rat plasma was developed based on a liquid chromatography and tandem mass spectrometry method. The separation of these seven compounds was carried out on a Shiseido CAPCELL PAK C(18) column using a mobile phase consisting of acetonitrile (containing 0.1% formic acid and water (containing 0.

View Article and Find Full Text PDF

Objective: To develop a HPLC method for the determination of evodiamine and rutacarpine in Zhuyu Hewei Zhitong capsules.

Method: The separation was performed at 30 degrees C on an Eclipse XDB-C18 column (4.6 mm x 150 mm, 5 microm) eluted with the mobile phase consisted of acetonitrile-water(45:55).

View Article and Find Full Text PDF

Objective: To establish a SPE-HPLC method for the determination and pharmacokinetic study of evodiamine and rutacarpine in rat plasma.

Method: A Kromasil C18 column (4.6 mm x 250 mm, 5 microm) was used with acetonitrile-water-tetrahydrofuran-acetic acid (51:48:1:0.

View Article and Find Full Text PDF