A challenge in designing a Brain-Computer Interface (BCI) is the choice of the channels, e.g. the most relevant sensors. Although a setup with many sensors can be more efficient for the detection of Event-Related Potential (ERP) like the P300, it is relevant to consider only a low number of sensors for a commercial or clinical BCI application. Indeed, a reduced number of sensors can naturally increase the user comfort by reducing the time required for the installation of the EEG (electroencephalogram) cap and can decrease the price of the device. In this study, the influence of spatial filtering during the process of sensor selection is addressed. Two of them maximize the Signal to Signal-plus-Noise Ratio (SSNR) for the different sensor subsets while the third one maximizes the differences between the averaged P300 waveform and the non P300 waveform. We show that the locations of the most relevant sensors subsets for the detection of the P300 are highly dependent on the use of spatial filtering. Applied on data from 20 healthy subjects, this study proves that subsets obtained where sensors are suppressed in relation to their individual SSNR are less efficient than when sensors are suppressed in relation to their contribution once the different selected sensors are combined for enhancing the signal. In other words, it highlights the difference between estimating the P300 projection on the scalp and evaluating the more efficient sensor subsets for a P300-BCI. Finally, this study explores the issue of channel commonality across subjects. The results support the conclusion that spatial filters during the sensor selection procedure allow selecting better sensors for a visual P300 Brain-Computer Interface.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10548-011-0193-y | DOI Listing |
JACS Au
January 2025
Department of Chemistry, Cancer Center at Illinois and Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, 61801 Illinois United States.
Porphyrins, known as the "pigments of life", have evolved from their natural roles into versatile tools for biomedical applications. The development of activatable porphyrins has significantly expanded their utility, enabling precise responses to a carefully selected target analyte. These advances have broadened their use in imaging, diagnosis, and therapy.
View Article and Find Full Text PDFRSC Adv
January 2025
Department of Chemistry, College of Science, King Saud University Riyadh 11451 Kingdom of Saudi Arabia.
In recent years, the fabrication of hydrazine sensors has received extensive attention because of the toxicity of hydrazine to the environment and human beings. It is thus important to design and develop efficient electrode modifiers for the construction of hydrazine electrochemical sensors. Herein, we reported the benign synthesis of a silver (Ag)-doped zinc-based zeolitic imidazolate framework (ZIF-8).
View Article and Find Full Text PDFNat Commun
January 2025
School of Emergent Soft Matter, South China University of Technology, Guangzhou, China.
Radioactive molecular iodine (I) is a critical volatile pollutant generated in nuclear energy applications, necessitating sensors that rapidly and selectively detect low concentrations of I vapor to protect human health and the environment. In this study, we design and prepare a three-component sensing material comprising reduced graphene oxide (rGO) as the substrate, silver iodide (AgI) particles as active sites, and polystyrene sulfonate as an additive. The AgI particles enable reversible adsorption and conversion of I molecules into polyiodides, inducing substantial charge density variation in rGO.
View Article and Find Full Text PDFJ Fluoresc
January 2025
Department of Chemistry, Madanapalle Institute of Technology & Science, Kadiri Road, Angallu, Madanapalle, 517325, Annamayya District, Andhra Pradesh, India.
A new Rhodamine functionalised Schiff Base sensor 3',6'-bis(diethylamino)-2-((4-hydroxybenzylidene)amino)spiro[isoindoline-1,9'-xanthen]-3-one (SBRB1) was designed and synthesized. The recognition ability of sensor SBRB1 towards Hg was studied by using UV-Vis and fluorescence spectroscopy. The fluorescence results showed that the sensor SBRB1 has specific selectivity as well as sensitivity towards Hg among other competitive metal ions as the fluorescence intensity at 479 nm quenched only in the presence of Hg.
View Article and Find Full Text PDFACS Sens
January 2025
Centre for Advanced Imaging (CAI) and Australian Institute for Bioengineering and Nanotechnology, ARC Training Centre for Innovation in Biomedical Imaging Technology, The University of Queensland, St. Lucia, Queensland 4072, Australia.
Recent examples of immune responses directed against the synthetic polymer poly(ethylene glycol) (PEG) have led to the development of biocompatible polymers, which are viewed as promising candidates to act as surrogate materials for use in biological applications, such as hydrophilic poly(2-oxazoline)s (POx). Despite this, the characterization of critical aspects of the immune response against these emerging materials is sparse, in part because no known monoclonal antibodies (mAbs) against this family of synthetic material have been reported. To advance the understanding of such responses, we report the successful isolation and characterization of hybridoma-derived mAbs with excellent specificity for different POx species and notable selectivity for highly branched polymer architectures over linear systems.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!