Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A 74-year-old male patient presented with complaints of fatigue, fever, and worsening health status. He had a 34-month history of cardioverter-defibrillator (ICD) implantation due to ischemic cardiomyopathy. Transthoracic and transesophageal echocardiography showed a mobile mass, 24 x 11 mm in size, consistent with a vegetation attached to the right ventricular ICD lead. Surgical removal of the electrode was considered to be highly risky for the patient, thus percutaneous removal was decided. Due to adhesions, manual traction of the lead with a standard stylet was ineffective. Complete lead extraction was accomplished using the Evolution Mechanical Dilator Sheath, which is a new mechanical sheath with a stainless steel bladed tip. No complications occurred during or after the procedure. Following a histopathologic diagnosis of vegetation, the patient received a six-week antibiotic therapy, after which a new ICD was implanted on the contralateral side. To our knowledge, this case represents the largest lead vegetation extracted by this new device. Although its safety should be validated by increasing number of cases, it seems that its simple use would make this device a new interesting tool among the instruments available for lead extraction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5543/tkda.2011.01356 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!