In the near future, it is likely that 3-dimensional (3D) surgical endoscopes will replace current 2D imaging systems given the rapid spreading of stereoscopy in the consumer market. In this evaluation study, an emerging technology, the autostereoscopic monitor, is compared with the visualization systems mainly used in laparoscopic surgery: a binocular visor, technically equivalent from the viewer's point of view to the da Vinci 3D console, and a standard 2D monitor. A total of 16 physicians with no experience in 3D interfaces performed 5 different tasks, and the execution time and accuracy of the tasks were evaluated. Moreover, subjective preferences were recorded to qualitatively evaluate the different technologies at the end of each trial. This study demonstrated that the autostereoscopic display is equally effective as the binocular visor for both low- and high-complexity tasks and that it guarantees better performance in terms of execution time than the standard 2D monitor. Moreover, an unconventional task, included to provide the same conditions to the surgeons regardless of their experience, was performed 22% faster when using the autostereoscopic monitor than the binocular visor. However, the final questionnaires demonstrated that 60% of participants preferred the user-friendliness of the binocular visor. These results are greatly heartening because autostereoscopic technology is still in its early stages and offers potential improvement. As a consequence, the authors expect that the increasing interest in autostereoscopy could improve its friendliness in the future and allow the technology to be widely accepted in surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1553350611411491DOI Listing

Publication Analysis

Top Keywords

binocular visor
16
laparoscopic surgery
8
autostereoscopic monitor
8
standard monitor
8
execution time
8
autostereoscopic
5
autostereoscopic three-dimensional
4
three-dimensional viewer
4
viewer evaluation
4
evaluation comparison
4

Similar Publications

Significance: Football helmet visors are popular among players and may increase safety. However, they may also be costly or impractical, or impair the evaluation of head and neck injury. Determining an objective list of vision-related clinical conditions may help meet risk-benefit ratios while increasing access to care to athletes with special needs.

View Article and Find Full Text PDF

Background: Considering the lack of universally accepted visual requirements for driving and for defining various grades of visual disability, the aim of this study is to propose a new method that provides a numerical score resulting from a combined assessment of the visual field and visual acuity loss obtained using a digital technology visor.

Methods: This study presents a new system for calculating the percentage of visual disability by combining binocular visual acuity and binocular visual field assessments. A new Global Vision Evaluation System digital technology visor uses standardized, reproducible criteria to produce well-defined, numerically expressed test results.

View Article and Find Full Text PDF

Objective: The focal length of available optical see-through (OST) head-mounted displays (HMDs) is at least 2 m; therefore, during manual tasks, the user eye cannot keep in focus both the virtual and real content at the same time. Another perceptual limitation is related to the vergence-accommodation conflict, the latter being present in binocular vision only. This paper investigates the effect of incorrect focus cues on the user performance, visual comfort, and workload during the execution of augmented reality (AR)-guided manual task with one of the most advanced OST HMD, the Microsoft HoloLens.

View Article and Find Full Text PDF

In the near future, it is likely that 3-dimensional (3D) surgical endoscopes will replace current 2D imaging systems given the rapid spreading of stereoscopy in the consumer market. In this evaluation study, an emerging technology, the autostereoscopic monitor, is compared with the visualization systems mainly used in laparoscopic surgery: a binocular visor, technically equivalent from the viewer's point of view to the da Vinci 3D console, and a standard 2D monitor. A total of 16 physicians with no experience in 3D interfaces performed 5 different tasks, and the execution time and accuracy of the tasks were evaluated.

View Article and Find Full Text PDF

Respiratory protection during high-fidelity simulated resuscitation of casualties contaminated with chemical warfare agents.

Anaesthesia

June 2008

GKT School of Medicine, King's College London, St Thomas's Campus, Department of Anaesthetics, Lambeth Palace Rd, London SE1 7EH, UK.

Emergency room personnel are threatened by secondary poisoning when treating victims affected by chemical warfare agents. Therefore, resuscitation skills practised with respiratory protection equipment in place require evaluation. We investigated the influence of wearing air-purifying respirators on the simulated resuscitation of chemical warfare agent casualties.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!